Range of Laboratory Equipment

Blood Bank Refrigerator LBBR-A20

  • Cabinet type :
  • Upright
  • Capacity :
  • 1008 L
  • Blood Storage Capacity :
  • 576 bags (450 capacity of each Blood Bags)

Drying Oven LDO-C13

  • Chamber Volume :
  • 250 L
  • Number of Shelves :
  • 3
  • Display Resolution :
  • 0.1℃

DIN abrasion tester TDAT-A10

  • Test arm weight :
  • 2.5 N
  • Additional Loads :
  • 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
  • Idler :
  • 150 mm

Pharmacy Refrigerator LPRF-A12

  • Temperature Range :
  • 8 °C to 15 °C
  • Temperature Set Point :
  • + 4 °C
  • Number of Wire shelves :
  • 5

Variable Volume Pipette VVP204L

  • Volume Range :
  • 10 - 100 μL
  • Increment :
  • 1 μL
  • Test Volume :
  • 100 μL <hr> 50 μL <hr> 10 μL

Muffle Furnace LMF-I41

  • Max. Temperature :
  • 1600 °C
  • Capacity :
  • 9 L
  • Heating Program :
  • 8 step

Solar Freezer LSF-A10

  • Capacity :
  • 100 Litres 
  • Additional Parts :
  • Solar panel: 200 W; Battery: 150 Ah; Charge controller: 12 V / 24 V - 15 A
  • Input Voltage :
  • DC 12 V / 24 V

Tube Furnace LTF-B32

  • Type :
  • Ultimate
  • Program memories :
  • 6
  • Heating program :
  • 16 steps

Oven Incubator LDI-A13

  • Capacity :
  • 136 L
  • Temperature Range :
  • a. As incubator : RT+5 °C - 80 °C <br> b. As oven : 80 °C - 220 °C
  • Shelves :
  • 2 pcs

Stainless Steel Water Bath LSBC-A11

  • Chamber volume :
  • 22 L
  • Temperature range :
  • RT ( + 5 ℃ ~ 99 ℃ )
  • Temperature stability :
  • ± 0.5 ℃

Benchtop Ion meter for I, LBIM-A26

  • Ion measurement range :
  • I range: 1×10<sup>8</sup>- 1M, 0.06 -127000 ppm
  • Ion measurement accuracy :
  • ± 1 % F.S.
  • Resolution :
  • 0.001, 0.01, 0.1, 1

See Saw Rocking Shaker LSSR-A10

  • Maximum Load Capacity :
  • 3 kg
  • Shaking Speed Range :
  • 10 - 80 rpm
  • Shaking Motion :
  • See Saw

Haematocrit Centrifuge LHC-A10

  • Max. Speed :
  • 12000 rpm
  • Max. RCF :
  • 15800 x g
  • Max. Capacity :
  • 24 pieces capillary vessel

Table Top Spectrophotometer LTS-A15

  • Wavelength Range :
  • 400 nm to 700 nm
  • Wavelength Interval :
  • 10 nm
  • Sensor :
  • High sensitivity silicon photodiode

Platelet Shaker LPS-A13

  • Shaking Speed Range :
  • 0 to 9 rpm
  • Capacity :
  • 48 bags
  • Overall Dimension :
  • 790 x 255 x 290 mm

Multi-range pocket TDS tester LPTS-A20

  • TDS range :
  • 0 - 20 ppt
  • TDS accuracy :
  • ± 1 % F.S.
  • TDS factor :
  • 0.1 to 1.0 (default 0.5)

Disintegration tester LDIT-A11

  • Number of basket lifting set :
  • 2 sets
  • Lifting frequency of the basket :
  • 30 to 32/ min
  • Lifting distance of basket :
  • 55 ± 1 mm

Biochemistry Analyzer LBCA-A10

  • Sample volume :
  • 1 ~ 100 µl , 0.1 µl / step
  • Reagent position :
  • 2 x 40
  • Reagent volume R1 :
  • 1 ~ 400 µl , 1 µl / step

Muffle Furnace LMF-K20

  • Max. Temperature :
  • 1750 °C
  • Capacity :
  • 6 L
  • Heating Program :
  • 4 step

Nano Spectrophotometer LNS-A20

  • Wavelength range :
  • 190 to 850 nm
  • Wavelength accuracy :
  • ± 1 nm
  • Wavelength Resolution :
  • 2 nm (FWHM at Hg 546 nm)