Range of Laboratory Equipment

Suspension Culture Flask SCF100L

  • Capacity :
  • 50 mL
  • Culture area :
  • 25 cm<sup>2</sup>
  • Cap :
  • Plug

Muffle Furnace LMF-B51

  • Max. Temperature :
  • 1100 °C
  • Capacity :
  • 40 L
  • Heating Program :
  • 4 step

Tablet Counting Machine LTCM-A10

  • Diameter of counting plate :
  • 400 mm
  • Hole No. of counting slide/range :
  • 5 to 100 (optional)
  • Production efficiency :
  • 10 to 20 vials/ min

Belt Drive Vacuum Pump LBDVP-A13

  • Pumping Speed :
  • 1800 L / min
  • Ultimate Pressure :
  • ≤ 1 Pa
  • Oil Capacity :
  • 3 L

Dispensing peristaltic pump LDPP-B11

  • Flow Range :
  • 0.06 ~ 6000 mL/min
  • Flow Accuracy :
  • 0.005
  • Speed Range :
  • 0.1 ~ 600 rpm

Plastic Reagent Bottle PRB102L

  • Capacity :
  • 10 mL
  • Material :
  • PE, PP
  • Color :
  • Natural / Black

Orbital Shaker LOS-A10

  • Maximum Load Capacity :
  • 2 kg at 20-150 rpm, 1 kg at 151-240 rpm
  • Shaking Speed Range :
  • 20 - 240 rpm
  • Platform Dimension :
  • 230 x 230 mm

Refrigerated Centrifuge LRF-A11

  • Max. Speed :
  • 5000 rpm
  • Max. RCF :
  • 4730 x g
  • Max. Capacity :
  • 4 x 300 ml

Flake Ice Maker LFIM-B11

  • Capacity :
  • 150 kgs / 24 hrs
  • Storage Bin Capacity :
  • 25 kgs
  • Load Capacity :
  • 48PCS/20' 96PCS/40HC

Biosafety Cabinet Class II B2 LBS2-B23

  • Max Opening :
  • 480 mm (20 inch)
  • Tested Opening :
  • Safety Height 200 mm(8 inch)
  • Inflow Velocity :
  • 0.53 ± 0.025 m/s

Muffle Furnace LMF-E50

  • Max. Temperature :
  • 1300 °C
  • Capacity :
  • 40 L
  • Heating Program :
  • 2 step

Rapid Low Temperature Circulating Bath LRTB-A71

  • Volume :
  • 20 L
  • Temperature range :
  • - 20 °C
  • Refrigerating capacity :
  • 5008 W

Biochemistry Analyzer LBCA-A10

  • Sample volume :
  • 1 ~ 100 µl , 0.1 µl / step
  • Reagent position :
  • 2 x 40
  • Reagent volume R1 :
  • 1 ~ 400 µl , 1 µl / step

Portable Autoclave LPOA-A13

  • Volume of Chamber :
  • 18 L
  • Working temperature :
  • 126 ℃
  • Heating mode :
  • Electrically heated

Vertical Laboratory Autoclave LVA-J11

  • Capacity :
  • 50 L
  • Sterilization Temperature :
  • 115 to 129 °C
  • Sterilization Pressure :
  • 0.165 MPa

Electronic Tearing tester TP-J21

  • Capacity :
  • 10 -16000 mN
  • Resolution :
  • 0.1 mN
  • Tearing arm :
  • 104 ± 1 mm

Class III Biosafety Cabinet LBCT-A10

  • External dimension (W×D×H) :
  • 1540×880×2000 mm
  • Internal dimension (W×D×H) :
  • 910×650×660 mm
  • Pre-filter :
  • Polyester fiber, washable

Tube furnace LTF-C35

  • Type :
  • Extended
  • Program Memories :
  • 4
  • Heating Program :
  • 4 stage

Benchtop Ion meter for Na, LBIM-A12

  • Ion measurement range :
  • Na range: 1 × 10<sup>5</sup> - 1 M, 0.1 - 23000 ppm
  • Ion measurement accuracy :
  • ± 0.5 % F.S.
  • Resolution :
  • 0.001, 0.01, 0.1, 1

Radio Frequency Identification Water Purification System LRFW-A10

  • Output of Pure water :
  • ≥ 10 L / hr.
  • Process :
  • Single Pass RO system
  • Configuration :
  • Benchtop