Our Petroleum testing equipment is used for quality analysis of petroleum products during upstream, midstream, and downstream production processes. It measures crude oil composition, crude oil fractions, analysis of fuel additives and oil contaminants, etc. Choose the petroleum testing equipment that best fits your needs.
Ambient temperature : | ≤ 35 °C |
Relative humidity : | ≤ 85 % |
Precision of titration tube : | Scale division is 0.02 ml |
Total power consumption : | ≤ 1200 W |
Measurement range : | ≥0.05 mg KOH/g |
Potential measurement range : | 0 to 1800.0 mV |
Burette volume : | 10 mL |
Minimum titration volume : | 0.001 ml |
Measurement range : | Room temperature ~ 150°C |
Stirring speed : | 0 ~ 1200 r / min |
Heating power : | 25 W |
Interior Dimension : | 360 × 250 × 545 mm |
Temperature controlling accuracy : | ≤ 0.5 ℃ |
Temperature controlling range : | Room temperature ~ 200 ℃ |
Power supply for illumination : | 5 V |
Power of motor : | 2 kW |
Electric Muffle Furnace : |
| ||||||||||||||||
Temperature controller : |
| ||||||||||||||||
Electric heating plate : |
|
Calorimeter type : | Isoperibol |
Temperature range : | 5 to 40°C |
Measurement range : | 5 to 40 MJ/ kg |
Operation Mode : | The outer barrel temperature is constant |
Calorimeter type : | Isoperibol |
Temperature range : | 5 to 40°C |
Measurement range : | 5 to 40 MJ/ kg |
Operation Mode : | A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode |
Calorimeter type : | Isoperibol |
Oxygen filling : | Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering |
Bomb volume : | 250 ml |
Analysis time : | < 8 min full test process: <10 min |
Calorimeter type : | Isoperibol |
Oxygen filling : | Semi-automatic |
Bomb volume : | 282 ml |
Analysis time : | 15 to 25 min |
Ambient Temperature : | 10 ℃ ~ 40 °C |
Relative Humidity : | ≤ 80 % |
Temperature Measurement- Full Scale : | Ambient temperature to 300 °C |
Temperature Measurement- Repeatability : | ≤ 8 °C |
Ambient Temperature : | 10 ℃ ~ 40 ℃ |
Relative Humidity : | ≤ 85 % |
Temperature Measurement- Full Scale : | Ambient temperature to ~ 400 ℃ |
Temperature Measurement- Repeatability : | ≤ 4 ℃ |
Capacity : | 2.0 kVA |
Speed of voltage increase : | 2 k V/ s |
Voltage inspection accuracy : | 0.01 |
Breakdown sensitivity : | < 0.1 kV |
Heating power : | 2 kW |
Cooling power : | 0.5 kW |
Steam temperature : | 0 to 400℃ |
Oven temperature : | 0 to 500℃ |
Samples : | 2 |
Oil bath cubage : | 30 L |
Angle between bomb and water surface : | 30 ° |
Speed of rotary assembly : | 100 ± 5 RPM |
Ambient temperature : | 10 °C ~ 40 °C |
Relative humidity : | ≤ 80 % |
Measurement Range : | Ambient Temperature ~ 250 °C |
Flash Point : | Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C |
Ambient temperature : | 10 °C ~ 40 ℃ |
Relative humidity : | ≤ 80 % |
Ignition Mode : | electron igniter / gas flame |
Temperature range : | Room Temperature ~ 300 ℃ |
Ambient temperature : | ≤ 30 ℃ |
Refrigeration speed : | > 40 °C / 10 min |
Repeatability for solidifying point : | ≤ 2 °C |
Repeatability for pour point : | ≤ 3 °C |
Measurement range : | 32 ℃ to 160 ℃ |
Ambient temperature : | 35 °C |
Temperature resolution : | 0.01 ℃ |
Beaker volume : | 1000 mL |
Experimental temperature range : | -50 to 70°C |
Test sample volume : | 50 ml |
Ambient temperature range : | 10 to 40°C |
Humidity : | ≤ 85% |
Temperature range : | Room temperature to 1000 ºC |
Temperature resolution : | 0.1 ºC |
Temperature fluctuation : | ±0.1 ºC |
Heating rate : | 1 ~ 80 ºC / min |
Volumetric analysis : | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml |
Automatic acid titration : | Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH |
Automatic potential control : | Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV |
Ambient temperature : | 0 ~ 35 ℃ |
Ambient temperature : | -10°C to 35°C |
Relative humidity : | ≤ 85 % |
Thermometer : | Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C |
Scale division : | 0.1 ℃ |
Porcelain crucible : | 30 ml |
Inner iron crucible : | 75 ml |
Outer iron crucible : | 190 ml |
Burner : | Mig Burner |
Bath type : | Four holes with a furnace |
Heating type : | Electric resistance furnace |
Temperature controlling range : | 0 ~ 520 °C |
Temperature controlling accuracy : | ± 5 °C |
Coking furnace : | Metal furnace |
Heating mode : | Electric heating |
Test unit : | 5 units |
Temperature range : | Ambient to 550°C |
Thermometer : | 6 ℃ ~ 400 ℃ |
Scale Division : | 2 °C |
Spout Aperture : | 0.6 ~ 0.8 mm |
Ambient Temperature : | -10 ℃ ~ 50 ℃ |
Light source : | 220 V, 100 W |
Temperature of grinding milk white light bulb : | 2750 ± 50 K |
Light hole( Φ14) : | 26 pieces |
Color comparing tube : | Φ32 mm |
Measuring range : | 0 to 700 taper degree (digital display table 0-70 mm) |
Timing device : | Timing error is less than ±0.1 s |
Resolution : | 0.01 mm |
Needle insertion accuracy : | ±1 cone insertion degree |
Sample hole : | 4 pieces |
Sample quantity : | 4 to 12 pieces |
Ambient temperature : | Room temperature to 35 °C |
Temperature controlling range : | Room temperature to 100°C |
Ambient Temperature : | 10°C to 35°C |
Measurement Range : | 0 to 100 mg |
Resolution : | 0.1 µg |
Max. Electrolysis Speed : | 40 µg /s |
Maximum current : | 400 mA |
Measurement range : | 3 µg to 9999.9 µg |
Resolution : | 0.1 µg |
Precision 1 : | ± 2 µg (3µg H2O to 20µg H2O) |
Ambient Temperature Range : | -10 to 35°C |
Relative Humidity : | ≤85% |
Distillation Flask : | 1000 ml |
Receiver : | 5 ml, with 0.05 ml graduation |
Air flow rate : | Not less than 150 L / h |
Max. Preset time : | 99 min 59 s (100 min) |
Chamber diameter of oven : | Φ22 mm |
Heating power of oven : | 1400 W × 2 |
Cubage of bath : | Ф300 × 380 mm |
Temperature controlling range : | 0 °C ~ 100 °C |
Temperature controlling accuracy : | ± 0.2 °C |
Temperature sensor : | Industrial platinum resistance, Pt100 |
Ambient temperature : | (-10)℃ ~ 35 ℃ |
Relative humidity : | ≤ 85 % |
Sample cup Inner diameter : | 31.0 ~ 32.0 mm |
Sample cup Wall thickness : | 1.0 ~ 1.5 mm |
Samples : | 8 |
Temperature : | 100 ℃ |
Temperature controlling accuracy : | 0.1 ℃ |
Flow meter : | 3 ± 0.3 L / H oxygen |
Graduated flasks : | 100 ml |
Distillation flask : | 125 ml |
Ambient temperature : | ≤ 35 °C |
Relative humidity : | ≤ 85 % |
Graduated flasks : | 100 ml |
Distillation flask : | 125 mL |
Ambient temperature : | ≤ 30 °C |
Relative humidity : | ≤ 85 % |
Graduated flasks : | 100 ml |
Scale division of graduated flask : | 1ml |
Distillation flask : | 125 ml |
Ambient temperature : | ≤ 35 °C |
Distillation flask : | 125 mL |
Ambient temperature : | Room temperature to 35 °C |
Relative humidity : | ≤ 85 % |
Thermometer : | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ |
Graduated flasks : | 10 ml and 100 ml |
Scale division of graduated flask : | 10 ml is 0.1 ml and 100 ml is 1 ml |
Ambient temperature : | (-10) °C ~ 35 °C |
Relative humidity : | ≤ 85 % |
Graduated flasks : | 100 ml |
Scale division of graduated flask : | 1 ml |
Outer diameter of distillation flask : | φ65 |
Refrigeration tube : | φ14 |
Ambient temperature : | ≤ 35 ℃ |
Relative humidity : | ≤ 85 % |
Heating power of electric furnace : | 250 W × 2 |
Total power consumption : | ≤ 700 W |
Beaker quantity : | 600 ml |
Ambient temperature : | (-10) °C ~ 40 °C |
Relative humidity : | ≤ 85 % |
Thermometer Measurement range : | (-5) °C ~ 300 °C |
Graduated Flask : | 200 ± 0.2 ml |
Standard Water Value : | 51 ± 1 s |
Temperature Range : | 0 ~ 100 °C |
Temperature Controlling Accuracy : | ± 0.2 °C |
Graduated Flask : | 100 ml |
Standard Water Value : | 51 ± 1 s |
Temperature Range : | 0 ~ 100 °C |
Temperature Controlling Accuracy : | ± 0.1 °C |
Graduated Flask : | 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials) |
Standard Water Value : | 51 ± 1 s |
Temperature Range : | 0 ~ 100 °C |
Ambient Temperature : | 10 °C ~ 40 °C |
Bath type : | Oil bath |
Bath capacity : | 5000 ml ± 50 ml |
Ambient temperature : | Room temperature to 35 °C |
Relative humidity : | ≤ 85 % |
Evaporation bath type and size : | Aluminum block bath, φ260 × 130 mm |
Holes for testing : | 3 pieces |
Size of holes for testing cylinder : | φ51 × 70 mm |
Flow rate display : | Flow meter |
Evaporation bath type and size : | Aluminum bath φ260 × 130 mm |
Holes for testing : | 5 pieces |
Size of holes for testing cylinder : | φ51 × 70 mm |
Working temperature : | 160 ℃ ~ 165℃ |
Temperature Range : | Ambient to 100°C |
Temperature Precision : | ± 0.1°C |
Air Flow : | 94 mL ± 5 mL/min, with flowmeters |
Timing Unit : | 0 to 99 min 59 s, resolution 1 s |
Freezing point range : | -54°C to 2°C |
Cold bath measurement temperature range : | -70° to 20°C |
Temperature controlling accuracy : | ±0.5°C |
Bath liquids stirring : | Electric |
Type : | Compact; Desktop |
Design : | Integrated |
Bath : | Metal bath (without water usage) |
Temperature control point of metal bath : | 100℃ ± 1℃ |
Power supply : | AC 220 V ± 5 % , 50Hz |
Measurement range : | 0 ~ 75 kV |
Voltage rising rate : | 3 kV ± 10 % / s |
Distance between electrodes : | 2.5 mm |
Ambient temperature : | 15 to 35°C |
Relative humidity : | ≤ 85% |
Capillary viscometer : | 6 capillary Pinkevitch viscometer tubes |
Stirring motor : | 1200 rpm |
Ambient temperature : | (-10) °C ~ 35 °C |
Relative humidity : | ≤ 85 % |
Capillary viscometer : | 11 pieces |
Stirring motor : | 6 W, 1200 rpm |
Ambient temperature : | (-10) °C ~ 35 °C |
Relative humidity : | ≤ 85 % |
Capillary viscometer : | 11 pieces |
Stirring motor : | 6 W, 1200 rpm |
Ambient temperature : | (-10) °C ~ 35 °C |
Relative humidity : | ≤ 85 % |
Capillary viscometer : | 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group |
Stirring motor : | 6 W, 1200 rpm |
Ambient temperature : | (-10) °C ~ 35 °C |
Relative humidity : | ≤ 85 % |
Capillary viscometer : | 11 pieces |
Stirring motor : | 6 W, 1200 rpm |
Ambient temperature : | 0 ~ 40 ºC |
Relative humidity : | 20 ~ 90 %, RH while 40 ℃ |
Temperature controlling accuracy : | ± 0.1 °C |
Timing range : | 0.0 s ~ 9999.9 s |
Sample hole : | 2 pieces |
Speed of stirring motor : | 1400 rpm |
Ambient temperature : | 10 to 35°C |
Temperature controlling range : | Room Temperature to 100°C |
Ambient temperature : | ≤ 30 °C |
Relative humidity : | ≤ 85 % |
Capillary viscometer : | 13 pieces |
Stirring motor : | 6 W, 1200 rpm |
Sample hole : | 4 pieces |
Speed of stirring motor : | 1400 rpm |
Speed for sample stirring : | 1000 ± 50 rpm |
Ambient temperature : | Room temperature to 35°C |
Dimension : | 390 x 260 x 590 mm |
Total power consumption : | ≤ 1200 W |
Power supply : | AC 220 V ± 10 %, 50 Hz |
Heating power of water bath : | 1000 W |
Potential measuring range : | (0 to ±1999.5) Mv |
Intrinsic error : | 0.1 % ±0.5 mV |
Input impedance : | Ri ≥1 × 1012 Ω |
Burette capacity : | 10 mL |
Refrigeration system : | New-type refrigeration compressor |
Controlling temperature of cold trough : | Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C |
Ambient temperature : | ≤ 30 ℃ |
Relative humidity : | ≤ 85 % |
Measuring Range For Aviation Gasoline : | 86.0 to 105.0/MON |
Measuring Range For Gasoline For Motor Vehicles : | National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON |
Measuring Range For Ethanol : | E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON |
Measuring Range For Automobile Diesel Fuels : | Cetane number: 25 to 75/CN Cetane index: 20 to 80/CI |
Thermometer : | 0 ℃ ~ 360 °C |
Scale Division : | 1 °C |
Ambient Temperature : | ≤ 35 °C |
Relative Humidity : | ≤ 85 % |
Temperature Range : | Ambient to 150℃ |
Temperature Precision : | ± 0.1°C |
Test Unit : | 2 units |
Heating Power : | 1800 W |
Heat capacity : | 14000 ~ 15000 J / K |
Temperature measurement range : | 10 ~ 35 ℃ |
Repeatability error : | ≤ 0.2 % (Grade C) |
Endured pressure in oxygen bomb : | 20 MPa |
Temperature controlling range : | 10 ℃ ~ 35 ℃ |
Temperature resolution : | 0.001 ℃ |
Mean value of heat capacity : | 15 kJ / K |
Ambient temperature : | 20 ℃ ± 5 ℃ |
Temperature measurement range : | 10 ~ 35 ℃ |
Repeatability error : | ≤ 0.2 % (Grade C) |
Endured pressure in oxygen bomb : | 20 MPa |
Operation environment temperature : | 15 ~ 28 ℃ |
Measurement range : | 0 to 600 penetration scale |
Timing controller : | 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec |
Time accuracy : | ± 0.1 seconds |
Resolution : | 0.01 mm |
Measurement range : | 0 to 600 penetration scale |
Timing controller : | 5 sec or 60 sec |
Time accuracy : | ± 0.1 seconds |
Resolution : | 0.01 mm |
Penetrometer : |
| ||||||||||||||||||
Circulatory Water Bath : |
|
Measurement range : | 0 to 600 penetration scale |
Timing range : | 0 sec to 60 sec |
Time accuracy error : | ≥ ± 0.1 seconds |
Resolution : | 0.1 penetration |
Ambient temperature : | Room temperature to 35 °C |
Relative humidity : | ≤ 85 % |
Timing range : | 1 s to 9 min 59 s |
Temperature controlling range : | Room temperature to 99.9 °C |
Ambient temperature : | Room temperature to 35 °C |
Relative humidity : | ≤ 85 % |
Temperature controlling range : | Room temperature to 99.9 °C |
Temperature controlling accuracy : | ± 1 °C |
Test bomb : | Two samples or a group of parallel samples |
Bath temperature : | 37.8 °C |
Temperature controlling accuracy : | 0.1 °C |
Dimensions : | 500 × 560 × 680 mm, 950 × 540 × 720 mm |
Ambient temperature : | ≤ 35 °C |
Relative humidity : | ≤ 85 % |
Temperature range : | 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C |
Aperture of ignition device : | 0.8 mm |
Measurement item : | motor gasoline and diesel |
measurement unit of octane is ON : | 40 to 120 |
Permissible error of octane : | ± 0.5 max |
Fluctuate range of octane : | ± 0.2 max |
Chamber quantity : | 2 chambers |
Chamber 01 temperature control : | Ambient to -51 ℃ |
Chamber 02 temperature control : | Ambient to -65 ℃ |
Temperature precision : | ±1°C |
Viscosity measurement range : | 10 ~ 2000000 MPa•s |
Ambient temperature : | 5 °C ~ 35 °C |
Ambient humidity : | Not more than 80 % |
Spindles : | Four spindles of No.1 ~ 4 |
Sample hole : | 4 pieces |
Ambient temperature : | Room temperature to 35°C |
Temperature controlling range : | 0 to 100°C |
Temperature controlling accuracy : | ± 1°C |
Refrigeration system : | New-type refrigeration compressor |
Controlling temperature of cold trough : | Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C |
Ambient temperature : | ≤ 30 ℃ |
Relative humidity : | ≤ 85 % |
Capacity : | 20 L |
Temperature range : | Ambient +5°C to 100°C |
Precision : | ± 0.1℃ |
Stirring range : | 1200 r/min |
Temperature controlling accuracy : | ± 0.5 °C |
Refrigeration system : | New-type refrigeration compressor |
Cold trough : | One trough with two baths, temperatures in two baths are equal |
Controlling temperature of cold trough : | Room temperature ~ (-70) °C |
Refrigeration system : | New-type refrigeration compressor |
Cold trough : | One trough with two baths, temperatures in two baths are equal |
Controlling temperature of cold trough : | Room temperature ~ (-70) °C |
Ambient temperature : | ≤ 30 ℃ |
Temperature controlling accuracy : | ± 0.5 ℃ |
Refrigeration system : | New-type refrigeration compressor |
Cold trough : | Two holes in one trough, and same temperature |
Ambient temperature : | ≤ 30 ℃ |
Temperature controlling accuracy : | ± 0.5 °C |
Refrigeration system : | New-type refrigeration compressor |
Cold trough : | One trough with two baths, temperatures in two baths are equal |
Controlling temperature of cold trough : | Room temperature ~ (-70) °C |
Vessel Volume : | 4000 ml × 2 |
Power of Vacuum pump : | 160 W |
Negative power : | 3.7 kPa(27.75 mmHg) |
Power of shaking machine : | 30 W |
Samples : | 6 |
Temperature controlling mode : | Automatic digital temperature |
Temperature controlling range : | Room temperature ~ 160 °C |
Temperature controlling accuracy : | ± 0.2 °C |
Ambient temperature : | 5 °C to 35 ℃ |
Relative humidity : | ≤ 85 % |
Cubage of buffer vessel : | 1000 ml |
Max. Residual pressure : | ≤ 2 mm Hg |
Operation temperature of water bath : | RT ~ 90 °C |
Temperature controlling accuracy : | ± 0.1 °C |
Dimensions : | 550 × 520 × 102 mm |
Pressure meter accuracy : | ± 0.4 % kPa |
Ambient Temperature Range : | ≤ 35°C |
Relative Humidity : | ≤ 85% |
Heating Mantle Cap Power : | 1000 W |
Sample Determination : | 1 at a time |
Ambient Temperature Range : | ≤ 35°C |
Relative Humidity : | ≤ 85% |
Heating Mantle Cap Power : | 1000 W × 2 |
Sample Determination : | 2 at a time |
Graduated flask : | 100 ml,50 ml |
Conical flask : | 100ml |
Separatory funnel : | 250ml |
Ambient temperature : | (-10 )°C to 35 °C |
Power supply : | AC 220 V ± 10 %, 50 Hz |
Temperature controlling range in water bath : | RT ~ 90 ℃ ± 5 ℃ |
Cooling bath temperature : | (-35) ℃ ± 1 ℃ |
Evaporation temperature : | 35 ℃ ± 1 ℃ |
Sample quantity : | 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm) |
Measurement time : | 60, 120, 240, 300, and 600 s at random |
Measurement range : | 7 ppm to 5 % |
Repeatability : | < 0.029 (S + 0.6) |