Plasma Autoclave LPA-B30 Catalog

Plasma Autoclave LPA-B30

Plasma Autoclave LPA-B30

Overview

Plasma Autoclave LPA-B30 is a H2O2 plasma sterilizer with microprocessor PLC controlled system, fully automated process with 60 L volume capacity. This Class II medical equipment offers manual door opening vertical type, rectangular chamber design. Chamber is made up of anti-corrosion type 5052 aluminum alloy with thickness ≥ 8mm, and is adopted with excellent thermal conductivity, to ensure 100% maintenance of gaseous hydrogen peroxide. Equipped with high and low temperature alarm system, pressure and temperature sensors, H2O2 resistant rotary vane vacuum pump for quality performance.

Features

  • - 7 inch touch screen LCD display
    Microprocessor PLC controlled system with fully automatic control system
    Manual door open mode, vertical type
    Built-in pressure sensor using imported sensor, automatic detection of chamber pressure
    Built-in temperature sensor automatically detects the temperature inside the cavity
    Built-In thermal printer to record & print real-time test data
    Exhaust oil mist filtration system
    High strength H2O2 resistant rotary vane vacuum pump
    USB interface to download and collect data by connecting it to PC
    Four universal wheel plus leveling foot design for easy movement and fixation of unit
    Use of explosion-proof flame retardant heating system
    Adapted with anti-explosion and fire resistance heating system, non-toxic environmental protection
    Large storage capacity: Disk capacity ≥ 8G
    Manual setting for different sterilization programs
    Use friendly appearance
Specifications
Chamber Volume 60 L
Sterilization temperature 50 ± 5°C
Working pressure -50 Pa
Sterilizing agent 60 % (H2O2) hydrogen peroxide
Sterilizing time 45 to 50 min
Installation environment temperature 5 to 45°C
Vacuum speed Absorb to – 50 Pa in five minutes
High anti-pressure valve 10 Pa
Door type Manual door opening, vertical
Operation height (for chamber design) ≤ 160 cm
Chamber material Anti-corrosion type 5052 aluminum alloy, thickness ≥ 8mm
Chamber temperature heating power 3.8 kW, preheating heating time ≤ 30min
Electrode material Aluminum alloy material 5052, sheet metal forming, thickness ≥ 2mm
Sealing door material Aluminum alloy material 5052, thickness ≥ 15mm
Carton material Carbon steel baking plastic powder and ABS
Main insulation ≥ 20mm rubber sponge, with a low thermal conductivity
Storage U disk capacity ≥ 8 G
Air filter accuracy ≤ 0.2 µm
Chamber dimension (L×W×H) 610 × 350 × 320 mm
Packaging dimension (L×W×H) 920 × 670 × 1450 mm
Power 2.6 kW
Power supply AC220 V, 50 Hz
Gross weight 270 kg
Applications :

Used in the hospital, pharmaceutical factory, lab, medical institutions for low temperature sterilization of heat sensitive materials.