\nHigh voltage switch control Ask An Expert Gas Chromatography LGC-B11 is a benchtop unit with advanced flow controller (AFC) technology. System has digital control mode and polar capillary columns to separate polar analytes. GC oven is capable of 9 temperature program ramps and hold steps, and features rapid cooling: 250 °C to 50 °C < 10 minutes. Accurate flow rate control via AFC has higher level repeatability of retention time and peak area, enabling specific level of analysis by means of dual FID detectors. Suitable for analysis of trace toxic compounds, monitoring and research in environmental protection, atmosphere and water source pollution. It is widely used for petrol-chemistry, environmental protection, epidemic prevention, pharmacology and scientific research.
\nBaseline signal display
\nIgnition coil control
\nDetection limit: \u22643 \u00d710 to 12 g\/s \n(Sample: n-hexadecane)
\nBaseline noise: \u2264 5 \u00d7 10 - 14 <\/sup> A
\nBaseline draft: \u2264 6 \u00d7 10 -13 <\/sup> A
\nDynamic range: 10 7 <\/sup>
\nRSD: \u2264 3 %"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">
\nBaseline signal display
\nIgnition coil control
\nDetection limit: \u22643 \u00d710 to 12 g\/s \n(Sample: n-hexadecane)
\nBaseline noise: \u2264 5 \u00d7 10 - 14 <\/sup> A
\nBaseline draft: \u2264 6 \u00d7 10 -13 <\/sup> A
\nDynamic range: 10 7 <\/sup>
\nRSD: \u2264 3 %"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">
Gas Chromatography LGC-B11 Catalog
Overview
Features
H2 and N2 mobile gas phase with AFC and constant pressure gas flow type
Equipped with capillary analysis system and capillary split sampler
Injection system incorporates diaphragm cleaning, split flow and auxiliary gas adjustment
Standard unit for high-speed analysis with polar capillary column
PEG-20M and FFAP stationary phase polar capillary columns can be coupled
Dual FID detector with automatic flame ignition and baseline signal display
Self-diagnostic and automatic fault recognition function
Multi-core and 32-bit embedded hardware system ensures the reliable operation
Equipped with chromatography workstation software to process data
Memory function can store 20 sample test data
RS232 interface and LAN port Specifications
Oven Maximum capacity: 22 L
Temperature range: RT + 5 ℃ to 400 ℃
Temperature accuracy: ± 0.1 ℃
Temperature program: 9-phase/ 10 platform
Program total time: 9999.9 min
Maximum temperature heating rate: 0.1 to 60 ℃/ min
Maximum cooling rate: ˂ 10 mins (250 to 50 ℃)Sample injector Temperature range: RT+ 7 ℃ to 420 ℃
Temperature control: Automatic
Injector type: Column or split
Maximum sample inlet: 3 pcs
Carrier gas flow type: Constant pressure
Pre column pressure range: 0 to 400 kPa
Pre column pressure accuracy: 0.1 kPa
Mobile phase flow range: H2: 0 to 200 ml/min, N2: 0 to 150 ml/minDetector Temperature range: RT + 7 ℃ to 420 ℃
Maximum installation: Dual detector
Flame ignition mode: Automatic
Flame Ionization Detector (FID): Logarithmic amplifier
High voltage switch control
Baseline signal display
Ignition coil control
Detection limit: ≤3 ×10 to 12 g/s
(Sample: n-hexadecane)
Baseline noise: ≤ 5 × 10 - 14 A
Baseline draft: ≤ 6 × 10 -13 A
Dynamic range: 10 7
RSD: ≤ 3 %Power supply AC 220 V ± 22 V, 50 Hz ± 0.5 Hz, 3000 W Packing dimension 1020 × 660 × 740 mm Gross Weight 82 kg Net weight 70 kg Standard Accessories :
Accessories no
Accessories name
1.
FID detector system
2.
Capillary injection system
3.
Chromatography workstation software
Optional Accessories :
Accessories no
Accessories name
1
Polar capillary columns PEG-20M
Stationary phase: 30 m × 0.32 mm
injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
2
Polar capillary columns FFAP
Stationary phase: 30 m × 0.32 mm
Injector temperature: 250 ℃
Oven temperature: 165 ℃
Detector: FID- 250 ℃
Inlet pressure: 0.04 Mpa
3
Syringe 1 ul
4
Syringe 5 ul
Applications :