Ask An Expert
Ion chromatograph system LICS-A20 is a modular design ion chromatograph with an upgraded circuit technology. Bipolar conductivity detector, improves the detection performance and stability of the instrument. Gradient elution system detects small molecules from complex samples. Built-in circulating stereo constant temperature and other technologies ensures accurate and reliable experimental data.
Ion Chromatographic Pump | Type: High pressure and low pulse double plunger tandem advection pump Maximum pressure: 35 MPa (PEEK) Pressure display accuracy: ≤ 0.1 MPa Flow stability: (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 % Flow range: 0.001 to 9.999 ml/ min Pressure pulse: ≤ 0.5% |
Conductivity detector | Type: Temperature Control and Bipolar Conductivity Detector Detection mode: Bipolar conductivity detection Cell volume: ≤ 0.8 µL Detection range: 0 to 35000 µS/ cm Detection resolution: ≤ 0.0020 nS/ cm Output voltage: - 6000 to +6000 mV (adjustable) Baseline noise: ≤ 0.05 % F.S. Baseline drift: ≤ 3 % FS/ 30 min Operating temperature range: Room temperature +5 to 60°C (41 to 140°F) Controlling temperature accuracy: ± 0.01°C Maximum pressure: 10 MPa Linear range: ≥ 103 Instruments linearity: ≥ 0.999 Quantitative repeatability: ≤ 1.0 % Qualitative repeatability: ≤ 1.0 % Minimum detectable concentration: Cl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml |
Flow system | Plastic flow path: Made of PEEK materials Six way Valve: PEEK material, 5000 psi pressure, independent automatic collection and flow function |
Degassing Device | Inner volume: 300 µl Degassing volume: 7.5 ml Maximum flow rate: 10 ml/ min Degassing efficiency: Degassing 90 % at 1ml/ min Organic tolerance: 1 |
Built-in Eluent Generator | Eluent types: KOH/ NaOH Eluent concentration range: 0.1 to 100 mM Concentration increment: 0.1 mM Flow rate change: 0.1 to 3.0 ml/ min Maximum pressure: 20 MPa Minimum pressure: 5 MPa |
Power supply | 150 W |
External dimension | 350 × 470 × 650 mm |
Net weight | 34 kg |
Gross weight | 40 kg |
Sr. No. | Name | Qty. |
1 | Ion Chromatography host | 1 |
2 | High pressure advection pump | 1 |
3 | Conductivity detector | 1 |
4 | Anion column | 1 |
5 | Anion guard column | 1 |
6 | Suppressor | 1 |
7 | Chromatography workstation | 1 |
8 | Column thermostat system | 1 |
9 | Spare parts kits | 1 |
10 | Vacuum degassing pump | 1 |
11 | Sand core filtration devices | 1 |
12 | Pretreatment column | 20 |
13 | 0.22 µm syringe filter | 200 |
14 | Eluent generator | 1 |
Accessories no. | Name |
1 | Auto sampler (20 samples) |
2 | Auto sampler (54 samples) |
3 | Auto sampler (108 samples) |
4 | Anion column |
5 | Guard column |
6 | Anion suppressor |
7 | Spare parts kits |
Used to detect small molecules (in the form of anion, cation) in food, chemical, mining, metallurgy, environment and other fields.