\n(0.5 to 1.0) ml\/ min \u2264 2 %
\n> 1.0 ml\/ min 2 %","Flow range":"0.001 to 9.999 ml\/ min","Pressure pulse":"\u2264 0.5%"}, Conductivity detector: {"Type":"Temperature Control and Bipolar Conductivity Detector","Detection mode":"Bipolar conductivity detection","Cell volume":"\u2264 0.8 \u00b5L","Detection range":"0 to 45000 \u00b5S\/ cm","Detection resolution":"\u2264 0.0020 nS\/ cm","Output voltage":"- 6000 to +6000 mV (adjustable)","Baseline noise":"\u2264 0.05 % F.S.","Baseline drift":"\u2264 3 % FS\/ 30 min","Operating temperature range":"Room temperature +5 to 60\u00b0C (41 to 140\u00b0F)","Controlling temperature accuracy":"\u00b1 0.01\u00b0C","Maximum pressure":"10 MPa","Linear range":"\u2265 103","Instruments linearity":"\u2265 0.999","Quantitative repeatability":"\u2264 1.0 %","Qualitative repeatability":"\u2264 1.0 %","Minimum detectable concentration":"Cl \u2264 0.0005 ug\/ ml
\nBrO3 \u2264 0.001 ug\/ ml
\nLi+ \u2264 0.001 ug\/ ml"}, Flow system: {"Plastic flow path":"Made of PEEK materials","Six way Valve":"PEEK material, 5000 psi pressure, independent automatic collection and flow function"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">
Ask An Expert
Ion chromatograph system LICS-A21 is a modular design ion chromatograph with high column efficiency and large column capacity and stable performance. With large conductivity detection range, it delivers more accurate results. Bipolar conductivity detector, improves the detection performance and stability of the instrument. Built-in circulating stereo constant temperature, and other technologies ensures accurate and reliable experimental data.
Ion Chromatographic Pump | Type: High pressure and low pulse double plunger tandem advection pump Maximum pressure: 35 MPa (PEEK) Pressure display accuracy: ≤ 0.1 MPa Flow stability: (0.2 to 0.5) ml/ min ≤ 3 % (0.5 to 1.0) ml/ min ≤ 2 % > 1.0 ml/ min 2 % Flow range: 0.001 to 9.999 ml/ min Pressure pulse: ≤ 0.5% |
Conductivity detector | Type: Temperature Control and Bipolar Conductivity Detector Detection mode: Bipolar conductivity detection Cell volume: ≤ 0.8 µL Detection range: 0 to 45000 µS/ cm Detection resolution: ≤ 0.0020 nS/ cm Output voltage: - 6000 to +6000 mV (adjustable) Baseline noise: ≤ 0.05 % F.S. Baseline drift: ≤ 3 % FS/ 30 min Operating temperature range: Room temperature +5 to 60°C (41 to 140°F) Controlling temperature accuracy: ± 0.01°C Maximum pressure: 10 MPa Linear range: ≥ 103 Instruments linearity: ≥ 0.999 Quantitative repeatability: ≤ 1.0 % Qualitative repeatability: ≤ 1.0 % Minimum detectable concentration: Cl ≤ 0.0005 ug/ ml BrO3 ≤ 0.001 ug/ ml Li+ ≤ 0.001 ug/ ml |
Flow system | Plastic flow path: Made of PEEK materials Six way Valve: PEEK material, 5000 psi pressure, independent automatic collection and flow function |
Power supply | 150 W |
External dimension | 350 × 470 × 510 mm |
Net weight | 26 kg |
Gross weight | 32 kg |
Sr. No. | Name | Qty. |
1 | Ion Chromatography host | 1 |
2 | High pressure advection pump | 1 |
3 | Conductivity detector | 1 |
4 | Anion column | 1 |
5 | Anion guard column | 1 |
6 | Suppressor | 1 |
7 | Chromatography workstation | 1 |
8 | Column thermostat system | 1 |
9 | Spare parts kits | 1 |
10 | Vacuum degassing pump | 1 |
11 | Sand core filtration devices | 1 |
12 | Pretreatment column | 20 |
13 | 0.22 µm syringe filter | 200 |
Accessories no. | Name |
1 | Auto sampler (20 samples) |
2 | Auto sampler (54 samples) |
3 | Auto sampler (108 samples) |
4 | Anion column |
5 | Guard column |
6 | Anion suppressor |
7 | Spare parts kits |
Used to detect small molecules (in the form of anion, cation) in food, chemical, mining, metallurgy, environment and other fields.