-86°C Ultra Low Temperature Chest Freezer LCF-D10 is an ultra-low temperature freezer comprised with 50 L of capacity, offers -40 to -86°C of temperature range with direct cooling method and manual defrost mode. Features microprocessor control system and SECOP compressor with EBM fan and mixture gas refrigerant, provides -86°C of cooling performance. Ergonomic design with high quality steel plate with spraying exterior and stainless-steel interior, has two-times foaming technology with 110 mm foaming insulation. Equipped with advanced alarm system and digital display, has delayed start and safe stop interval protection along with keyboard lock and password access.
Cabinet type | Chest |
Capacity | 50 L |
Temperature Range | -40 to -86°C |
Ambient Temperature | 16 to 32°C |
Cooling Performance | -86°C |
Cooling Method | Direct Cooling |
Defrost Mode | Manual |
Refrigerant | Mixture Gas |
Climate Class | N |
Controller | Microprocessor |
Display | Digital Display |
Compressor | 1 pc. |
Alarm System | High/Low temperature, High ambient temperature, Power failure, Low battery, Sensor failure, Condenser overheating alarm, Built-in datalogger USB failure, Main board communication error |
External Material | High Quality Steel Plates with Spraying |
Internal Material | Stainless-steel |
Insulation | 110 mm |
Casters | 4 |
Door Lock with Key | Yes |
Access Port | 1 pc. Φ25 mm |
Data Logging/Interval/Recording Time | USB/Record every 10 minute / 2 years |
Backup Battery | Yes |
Protection Function | Delayed start and safe stop interval protection |
Power Supply | 220 to 240 V, 50 Hz |
Rated Current | 5.3 A |
Internal Dimension (W×D×H) | 430×305×425 mm |
External Dimension (W×D×H) | 677×606×1081 mm |
Packaging Dimension (W×D×H) | 788×720×1283 mm |
Net Weight | 74 kg |
Gross Weight | 123 kg |
RS485
Remote alarm contact
Chart Recorder
CO2 Backup System
-86°C Ultra Low Temperature Chest Freezer is used across hospitals, health and epidemic prevention system, scientific research institutes, biological engineering, laboratory in colleges and universities, military industrial enterprises, etc.