-5<\/sup>","Baseline drift ( Static ) Au \/ h":"\u2264 1.5 x 10 -4<\/sup>","Minimum detection limit":"\u2264 4 x 10 -8<\/sup>","Power":"100 W","Power supply":"90 V \/ 50 to 60 Hz","Dimension":"460 \u00d7 260 \u00d7 190 mm","Weight":"9.2 kg"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">
Ask An Expert Analytical HPLC-A7835 system is equipped with a flow rate range of 0.0001 to 10 ml per minute. Integrated with a single and dual wavelength UV-Vis detector with a range of 190 to 800 nm that analyzes sample’s absorption at different wavelengths and a high pressure pump providing continuous consistent flow. Built in column heater provides reproducible retention time. Used in pharmaceutical analysis, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity analysisAnalytical HPLC-A7835 Catalog
Overview
Features
Low pressure gradient
Detector ( Deuterium or tungsten lamp )
Simultaneous working of deuterium and tungsten lamp
Automatic sample injector ( Autosampler )
External pump control by panel or computer software
Auto save last detected records by the detector
10 point calibration pump for linear pressure control
Error alarm function for over pressure ,under pressure and leakage Specifications
Pump Specifications Model No: HPP-B1
Flow rate range: 0.0001 to 10 ml / min
Maximum pressure: 42 MPa , 0 to 5 ml / min
Column size: 4.6 × 250 mm
Sample size: 5 μm
Pressure pulsation: ≤ 1.5 % at 10 MPa
Flow rate accuracy: ± 0.2 % at 1 ml / min
Flow rate repeatability %: ≤ 0.15
Gradient accuracy %: ± 2
Gradient repeatability %: ≤ 0.2
Dimension: 450 × 260 × 190 mm
Power supply: 90 V to 240 V
Weight: 11.2 kgDetector Specifications Model No: HPD-B2
Wavelength range: 190 to 800 nm
Wavelength accuracy: ± 0.75 nm
Wavelength repeatability: 0.2 nm
Band width: 8 nm
Optical path: 10 nm
Deuterium lamp: 190 to 400 nm
Tungsten lamp: 400 to 800 nm
Baseline noise ( Static ) Au: ≤ ± 0.5 × 10 -5
Baseline drift ( Static ) Au / h: ≤ 1.5 x 10 -4
Minimum detection limit: ≤ 4 x 10 -8
Power: 100 W
Power supply: 90 V / 50 to 60 Hz
Dimension: 460 × 260 × 190 mm
Weight: 9.2 kgStandard Accessories :
Accessory
Quantity
Pump
2
UV-Vis detector ( without flow cell )
1
Analytical flow cell
1
Injection valve
1
20 μl sample loop
1
4.6 x 250 mm ( 5μm ) analytical column
1
Solvent tray
1
Binary gradient kit
1
Mixing chamber
1
Optional Accessories :
Accessory
Quantity
Autosampler
1
Fraction collector
1
Column oven
1
Applications :