2 <\/sub>O, R.T., 8.5 MPa)","Flow Precision":"RSD \u2264 0.06% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5MPa)","Maximum Pressure":"63 MPa","Pressure accuracy":"\u2264 \u00b1 3.0 %","Pressure pulsation":"\u2264 0.1 MPa","Composition rang":"0 to 100 %","Composition precision":"\u2264 0.3 % RSD"}, UV/VIS Detector: {"Wavelength Range":"190 to 800 nm","Wavelength Repeatability":"\u2264 0.1 nm","Wavelength Accuracy":"\u2264 \u00b1 1.0 nm","Band Width":"6 nm","Response Time":"0.0 s to 5 s","Baseline Noise":"\u2264 \u00b1 0.25 \u00d7 10-5 <\/sup> AU(empty cell, 254 nm, 1.0s)","Drift":"\u2264 0.5 \u00d7 10-4 <\/sup> AU\/h (empty cell, 254 nm, 60 min)","Path length":"10 mm(analytical cell)","Light Source":"Deuterium Lamp and Tungsten Lamp"}, Data-processing Workstation: System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA. Dive into the product details to learn more. Visit labtron.cc for additional information!"> Analytical HPLC System LAHS-A10 Catalog | Labtron 2 <\/sub>O, R.T., 8.5 MPa)","Flow Precision":"RSD \u2264 0.06% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5MPa)","Maximum Pressure":"63 MPa","Pressure accuracy":"\u2264 \u00b1 3.0 %","Pressure pulsation":"\u2264 0.1 MPa","Composition rang":"0 to 100 %","Composition precision":"\u2264 0.3 % RSD"}, UV/VIS Detector: {"Wavelength Range":"190 to 800 nm","Wavelength Repeatability":"\u2264 0.1 nm","Wavelength Accuracy":"\u2264 \u00b1 1.0 nm","Band Width":"6 nm","Response Time":"0.0 s to 5 s","Baseline Noise":"\u2264 \u00b1 0.25 \u00d7 10-5 <\/sup> AU(empty cell, 254 nm, 1.0s)","Drift":"\u2264 0.5 \u00d7 10-4 <\/sup> AU\/h (empty cell, 254 nm, 60 min)","Path length":"10 mm(analytical cell)","Light Source":"Deuterium Lamp and Tungsten Lamp"}, Data-processing Workstation: System contain the tables for regular samples
Equipped with Internal and external standard calculation process
Automatic display, print, export of data and starting of another program on completion on measurement
Observe with the condition of 21 CFR part 11 directive of the FDA. Dive into the product details to learn more. Visit labtron.cc for additional information!">

Ask An Expert

Analytical HPLC System LAHS-A10 Catalog

Analytical HPLC System LAHS-A10

Analytical HPLC System LAHS-A10

Overview

Analytical HPLC System LAHS-A10 features Quaternary Low Pressure Pump with 0.001-10 ml/min pump flow rate. Incorporated UV-Vis detector with a range of 190 to 800 nm that examines sample absorption at different wavelengths and a high pressure pump providing continuous stable flow. This HPLC system offers high speed accuracy, resolving power, detection, quantification, convenience and applicability to new sample types. 

Features

  • - UV-Vis detector with a range of 190 to 800 nm
    Consist of Quaternary Low Pressure Pump
    Advance and intellectual HPLC system
    Excellent Flow Accuracy and Pressure Accuracy
    Column oven with greater capacity of 3 column with maximum thickness ID10 × 250 mm
    Fast and stable UDP communication protocol, can be used for instrument remote control
    Enhancement of up to 5 mm stroke of plunger rod with good performance and high pressure constant flow pump or parallel pump head
    Complies with FDA 21 CFR part 11
Specifications
Pump specificationType: Quaternary Low Pressure Pump
Flow Rate Range: 0.001 to 10.000 ml/min, in 0.001ml increments
Flow Accuracy: ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)
Flow Precision: RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa)
Maximum Pressure: 63 MPa
Pressure accuracy: ≤ ± 3.0 %
Pressure pulsation: ≤ 0.1 MPa
Composition rang: 0 to 100 %
Composition precision: ≤ 0.3 % RSD
UV/VIS DetectorWavelength Range: 190 to 800 nm
Wavelength Repeatability: ≤ 0.1 nm
Wavelength Accuracy: ≤ ± 1.0 nm
Band Width: 6 nm
Response Time: 0.0 s to 5 s
Baseline Noise: ≤ ± 0.25 × 10-5 AU(empty cell, 254 nm, 1.0s)
Drift: ≤ 0.5 × 10-4 AU/h (empty cell, 254 nm, 60 min)
Path length: 10 mm(analytical cell)
Light Source: Deuterium Lamp and Tungsten Lamp
Data-processing WorkstationSystem contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA
System Kits1 Set Combined A/D converters Combined vacuum degasser and 4 channel
Power SupplyAC 110 /220 V ±1 0 %, 50/60 Hz
Dimension710 × 583× 500mm; 770 × 450 × 700 mm
Weight156 kg
Standard Accessories :

Degasser

Optional Accessories :

Accessories no. Name
1 Column oven
2 Auto sampler
3 Degasser
4 Diode Array Detector
5 Refractive Index Detector
6 Evaporative Light Scattering Detector
7 Fluorescence Detector

Applications :

High Performance Liquid Chromatography system has been widely used in Research and Development, pharmaceutical, food nutrient analysis of amino acids and sugars, detection of food contaminants, environmental pollutant and chemical product purity.

Enquiry Now