-5<\/sup>AU","Baseline drift":"\u2264 2.0 \u00d7 10-4<\/sup>AU\/h","Minimum detectable concentration":"4.0 \u00d7 10-9<\/sup> g\/mL","Detector cell":"Optical path: 10 mm
\nVolume: 10 \u00b5L","Light source":"Deuterium lamp","Power consumption":"100 W","Voltage":"AC 110 V\/ 220 V \u00b1 10 %, 50\/60 Hz","Packing Dimensions (W \u00d7 D \u00d7 H)":"600 \u00d7 440 \u00d7 380 mm
\n2 \u00d7 (600 \u00d7 410 \u00d7 300 mm","Gross weight":"54 kg"}. Dive into the product details to learn more. Visit labtron.cc for additional information!"> Analytical HPLC System LAHS-B10 Catalog | Labtron -5<\/sup>AU","Baseline drift":"\u2264 2.0 \u00d7 10-4<\/sup>AU\/h","Minimum detectable concentration":"4.0 \u00d7 10-9<\/sup> g\/mL","Detector cell":"Optical path: 10 mm
\nVolume: 10 \u00b5L","Light source":"Deuterium lamp","Power consumption":"100 W","Voltage":"AC 110 V\/ 220 V \u00b1 10 %, 50\/60 Hz","Packing Dimensions (W \u00d7 D \u00d7 H)":"600 \u00d7 440 \u00d7 380 mm
\n2 \u00d7 (600 \u00d7 410 \u00d7 300 mm","Gross weight":"54 kg"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">

Ask An Expert

Analytical HPLC System LAHS-B10 Catalog

A PHP Error was encountered

Severity: 8192

Message: json_decode(): Passing null to parameter #1 ($json) of type string is deprecated

Filename: website/singlecatalog.php

Line Number: 25

Backtrace:

File: /home2/srekosmy/public_html/labtron.cc/application/views/website/singlecatalog.php
Line: 25
Function: json_decode

File: /home2/srekosmy/public_html/labtron.cc/application/controllers/Website.php
Line: 465
Function: view

File: /home2/srekosmy/public_html/labtron.cc/application/controllers/Website.php
Line: 68
Function: singlecatalog

File: /home2/srekosmy/public_html/labtron.cc/index.php
Line: 318
Function: require_once

Analytical HPLC System LAHS-B10

Analytical HPLC System LAHS-B10

Overview

Analytical HPLC System LAHS-B10 is a unit equipped with LCD display UV-Visible wavelength range of 190 nm to 700 nm and double plunger reciprocating pump system for constant flow pump. It has isocratic kit system for test result accuracy. Consists of separate workstation, sample injector and front mounted self-locking switch. Deuterium lamp is used as light source with valve mounting frame. It is ideally used in the detection of compounds in pharmaceutical industries, research institute, food industries, and petroleum industries, etc.

Features

  • - Double plunger reciprocating pump system
    Isocratic system kits
    Sample injector: 1 set
    Deuterium lamp light source
    Separate workstation
    LCD display for value observation
    Front mounted self-locking switch
    Output: USB port
    Compact and easy to install
Specifications
High Pressure Constant Flow Pump {"Double plunger reciprocating pump":"1 set","Flow range":"0.001 to 10.00 mL\/min","Setting step size":"0.001 mL\/min","Flow accuracy":"\u2264 \u00b1 0.3 %","Flow stability":"RSD \u2264 00.1 %","Maximum pressure":"42 MPa","Display pressure error":"\u2264 1.0 %","Pressure fluctuation":"\u2264 1.0 %","Power consumption":"80 W"}
UV/Visible Detector {"Wavelength range":"190 to 700 nm","Wavelength repeatability":"\u00b1 0.1 nm","Band width":"8 nm","Response time":"0 to 4.9 seconds","Linearity range":"1.8 AU (5 %)","Baseline Noise":"\u2264 \u00b1 1 \u00d7 10-5<\/sup>AU","Baseline drift":"\u2264 2.0 \u00d7 10-4<\/sup>AU\/h","Minimum detectable concentration":"4.0 \u00d7 10-9<\/sup> g\/mL","Detector cell":"Optical path: 10 mm
\nVolume: 10 \u00b5L","Light source":"Deuterium lamp","Power consumption":"100 W","Voltage":"AC 110 V\/ 220 V \u00b1 10 %, 50\/60 Hz","Packing Dimensions (W \u00d7 D \u00d7 H)":"600 \u00d7 440 \u00d7 380 mm
\n2 \u00d7 (600 \u00d7 410 \u00d7 300 mm","Gross weight":"54 kg"}
Optional Accessories :

No Accessory name
1 Column oven

Applications :

Widely used in pharmaceutical, petroleum, research institute, food industrial applications in separation and detection of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

Enquiry Now