Ask An Expert
ICP Spectrometer LICP-B10 is an instrument which measures elements in ppb levels with least interference and reduces the time taken for analysis by detecting 5 to 6 elements in 1 min. Excellent analytical precision, high optical resolution, fully automated, wide wavelength range with 2400 line grating, powerful analysis software, high performance solid-state RF system, high accuracy etc. are some of the characteristic features. The equipment consist of a Scott-type spray chamber, quartz torch, spectrophotometer with Czerny-Turner monochromator, detector with photomultiplier tube and data processing system which allows multi-element measurement along with high resolution. It finds applications in environmental, food safety, metallurgy, pharmaceutical etc. fields.
| Monochromator Specifications |
{"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"} |
| Solid State Power Specifications |
{"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"} |
| Technical Specifications |
{"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"} |
| Control Circuit | {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"} |
| Working Environment | {"Temperature for storage and transportation":"15\u00b0C to 25\u00b0C","Humidity for storage and transportation":"\u2264 70%","Power Stability":"220 \u00b1 10V; 50 to 60 V","Humidity":"\u2264 70%","Temperature":"15\u00b0C to 30\u00b0C"} |
| Other Details |
{"Packaging Dimension and Gross Weight (4 case)":"1st case: 188 \u00d7 111 \u00d7 105 \/ 348 kg 2nd case: 60 \u00d7 60 \u00d7 55 \/ 25 kg 3rd case: 59 \u00d7 67 \u00d7 97 \/ 80 kg 4th case: 38.5 \u00d7 38.5 \u00d7 63 \/ 47 kg"} |
It used for quantitative and qualitative analysis of elements in the given sample. Various fields like petrochemicals, pharmaceuticals, agriculture, environmental, food industry, metallurgy, processing industry etc. require it for several operations.