Shaking Incubator (Stack Type) LSI-D11

Shaking Incubator (Stack Type) LSI-D11

Overview

Shaking Incubator (Stack Type) LSI-D11 has a temperature range from RT + 5 °C to 60 °C and its rotating speed is from 50 to 300 rpm. The vibrating range of the device is φ 25 mm. It stand with a maximum capacity of 2000 ml × 12 or 1000 ml × 18 or 500 ml × 35 or 250 ml × 40 with a temperature accuracy of ± 0.1 °C. The device uses microprocessor PID control system for smooth functioning. Additionally it has an automatic alarm system for over-temperature, over-speed and for over-current to protect the device. It also consist of advanced Unishaft drive with low noise operation. The inner wall is made of stainless steel and has good corrosion resistance. And the external wall is made of cold-rolled steel with anti-bacteria power coating.

Features

  • - Advanced Unishaft drive with low noise operation
    Alarm function is available for audio as well as visual
    When the motor is overheating and temperature is out of control automatic power-off protection system is activated
    Shaking plate of the device is made of electroplating aluminum, anti-rust or anti-corrosion
    Eight self-compiled programs, with different speed and time setting
    Automatic operation, auto-stop, timing, time display, parameters memory and recovery function
    LCD display is used to show the result of the experiment
Specifications
Display LCD
Circulation Mode Forced convection
Shaking Mode Rotatory Shaking
Drive Mode Unishaft drive
Temperature Range RT + 5 °C to 60 °C
Temperature Accuracy ± 0.1 °C
Temperature Uniformity ± 0.25 °C
Rotating Speed 50 to 300 rpm
Rotating Accuracy ± 1 rpm
Vibration Range Φ 25 mm
Refrigerant /
Cooling Consumption /
Heating Consumption 800 W
Timing Range 0 to 500 hours
Shaking Plate Size 850×560 mm
Standard Capacity 250ml × 40
Maximum Capacity 2000 ml × 12 or 1000 ml × 18 or 500 ml × 35 or 250 ml × 40
Internal Material Mirror stainless steel
External Material Cold-rolled steel with anti-bacteria power coating
Safety function Audio and visual alarm for over-temperature; Alarm for over-speeds; Independent over-temperature protector; Shutdown protection for door opening; Leakage or over-current protection
Consumption 960 W
Power Supply AC 110 V / 220 V ± 10 %, 50 / 60 Hz
Internal Size 870×550×395 (per unit) mm
External Size 1300×910×980 mm (per unit)
Package Size 1400×1010×1130 mm (per unit)
Gross Weight 410 kg (per unit)
Standard Accessories :

Acc. No. Name Quantity
1 250 ml Flask Clamp 40 pcs

Optional Accessories :

Optional Acc. No. Name
1 250 ml Flask Clamp
2 500 ml Flask Clamp
3 1000 ml Flask Clamp
4 2000 ml Flask Clamp

Applications :

Shaking Incubator (stack type) is used for the studies of solubility. It can be also used for growth of any kind of cell including bacterial cultures, tissue cultures and yeast incubator.