50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}, Dimension with 550 × 300 × 250 mm, and Display with LCD (320 × 240). ">
Ask An Expert
Multi parameter water quality analyzer LMWA-A10 with portable suitcase design, directly measures turbidity, chemical oxygen demand, ammonia and total phosphorous content of water sample, without any power supply. Incorporated with a 15 samples intelligent reactor, it meets the demand of user for testing large quantities of water samples. Its rated power of reactor is adjusted, according to the quantity of load.
| COD | {"COD determination range":"2 to 10000 mg\/ L","COD measurement accuracy":"COD < 50 mg\/ L, \u2264 \u00b1 10 % \nand \nCOD > 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"} |
| Ammonia nitrogen | {"Ammonia nitrogen determination range":"0.02 to 60 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"} |
| Total phosphorous | {"Total phosphorous determination range":"0.002 to 20 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"} |
| Turbidity | {"Turbidity determination range":"0.5 to 400 NTU","Turbidity measurement accuracy":"\u2264 \u00b1 5 %","Turbidity minimum detection limit":"0.1 NTU","Turbidity measurement time":"1 minute","Turbidity repeatability":"\u2264 \u00b1 5 %","Consumables for colorimetric turbidity measurement":"Colorimetric Cuvette"} |
| Light source life | 100000 hours |
| Optical stability | ≤ 0.001 A/ 10 min |
| No. of curves | 166 |
| Storage data | 12000 |
| Display | LCD (320 × 240) |
| Interface | USB |
| Power supply | AC 200 V |
| Dimension | 550 × 300 × 250 mm |
| Gross Weight | 21 kg |
Used in on-field water quality analysis based on COD, ammonia nitrogen, total phosphorous and turbidity parameters.