Portable Spectrophotometer LSP-C10 adopts 1000 line precision blazed grating as the spectroscopic element, the silicon photocell array with large photosensitive area as the detector. The full spectrum led with high life as the light source, and the optical resolution is less than 10 nm in the visible light range. Under the condition of d/8 geometric optical illumination recommended by CIE, spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples. It has stable performance, accurate color measurement and powerful function.
Reflect | 8º(diffused illumination, 8 degree viewing angle) |
Optical Geometry | SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source |
Standards | ISO7724-1, ASTM E1164, DIN5033 Teil7 |
Integrating Sphere Size | Φ 40 mm |
Light Source | Combined full spectrum LED light source, UV light source |
Spectrophotometric Mode | Flat Grating |
Sensor | Silicon photodiode array (double row 40 groups) |
Wavelength Range | 400 to 700 nm |
Wavelength Interval | 10 nm |
Semi band Width | 10 nm |
Measured Reflectance Range | 0 to 200% |
Measuring Aperture | MAV Φ8 mm / Φ10 mm SAV Φ4 mm / Φ5 mm |
Specular Component | SCI & SCE |
Color Space | CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy,DIN Lab99 Munsell (C/2) |
Color Difference Formula | ΔE×ab, ΔE×uv, ΔE×94, ΔE×cmc(2:1), ΔE×cmc(1:1), ΔE×00, DINΔE99, ΔE (Hunter) |
Other Colorimetric Index | WI (ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness, 555 tone classification |
Illuminant | D65, A , C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30) |
Observer Angle | 2° / 10° |
Measuring Time | About 1.5 s (Measure SCI & SCE about 3.2 s) |
Repeatability | Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) Chromaticity value: MAV/SCI, within ΔE × ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
Inter-instrument Error | MAV/SCI, Within ΔE×ab0.15 (Average for 12 BCRA Series II color tiles) |
Measurement Mode | Single Measurement, Average Measurement(2 to 99 times) |
Locating Method | Camera Locating, stabilizer cross position |
Displayed Data | 3.5 inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Bluetooth 4.2 |
Data Storage | Standard 1000 Pcs, Sample 30000 Pcs |
Language | English |
Operating temperature | 0 to 40ºC |
Operating humidity | 0 to 85 %RH |
Dimension | 129 × 76 × 217 mm |
Battery | Li-ion battery, 6000 measurements within 8 hours |
Weight | Approx. 600 g |
Accessories no. | Name |
---|---|
1 | Power Adapter |
2 | User Guide |
3 | PC Software |
4 | USB cable |
5 | White and Black Calibration Cavity |
6 | Protective Cover |
7 | Wrist strap |
8 | 8 mm flat aperture |
9 | 8 mm tip aperture |
10 | 4 mm flat aperture |
11 | 4 mm tip aperture |
Portable Spectrophotometer is used in plastic electronics, paint and coating, textile printing and dyeing, printing paper, automobile, medical treatment, cosmetics and food industries, as well as scientific research institutions and laboratories etc.