Ask An Expert
Table top spectrophotometer LTS-A10 is a high performance spectrophotometer with test caliber (top port) upward. The solid samples (paper sheets, cloth) can be placed directly on the measurement port & particles like pellets, tablets, powder (dye, food powder, chemical powder), paste (thick paste, opaque samples can be placed in a round shape plates & then in the mouth of the measurement unit. It is adopted with every test calibration ETC technology, where the standard white boards is included in the optical system for reliable, accuracy of every measurement.
Illumination system | d/8 (Diffused lighting, 8° observation angle) SCS optical engine (light splitting and integration system) ETC (real time calibration technology ) SCI (specular reflection included) & SCE(specular reflection excluded) simultaneous measurement |
Size of integrated sphere | 40 mm, alvan diffused reflection surface coating |
Illumination light source | CLED |
Sensor | Dual light path sensor array |
Light source | A, C, D50, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, DLF, TL183, TL184, NBF, U30, CWF |
Wavelength range | 400-700 nm |
Wavelength interval | 10 nm |
Half spectral width | 5 nm |
Reflectivity range & resolution | 0 to 200%, 0.01% |
Observation Angle | 2°/10° |
Measurement caliber | |
Measurement time interval | 0.5 s |
Measurement time | 1 s |
Measuring aperture | 11 mm |
Color space | CIE-L*a*b, L*C*h, L*u*v, XYZ, Yxy, Reflectance, hunterlab, munsell Mi, CMYK |
Color difference formula | ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*94,ΔE*00,ΔEab(Hunter),555 ,color classification |
Other colorimetric indices | WI (whiteness) (ASTM E313-10,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger,
Ganz, Stensby) YI (yellowness) (ASTM D1925,ASTM E313-00,ASTM E313-73) Tint(ASTM E313,CIE,Ganz) Metamerism index Milm, adhesive/changing color fastness, ISO illuminance, 8 gloss, A density, T density |
Repeatability | light splitting reflectivity:standard deviation within 0.08% color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.03 |
Color matching system | Matches |
UV light source | Not included |
Work temperature range | 0 to 45℃, relative humidity 80% or below( at 35°C ),no condensation |
Storage temperature range | 25℃ to 55℃ relative humidity 80% or below(at 35°C ),no condensation |
Battery capacity | Rechargeable, 20000 continuous tests, 7.4V/6000mAh |
Data being displayed | SPD distribution/data,samples color values,color difference values/graph,pass/fail results,color error tendency,color simulation display measurement area,history data color simulation,manual input standard sample generate measurement report |
Interface | USB |
Display | 5.5 inch TFT touch screen |
Data storage | 20000 test results |
Light source longevity | 10 years, 3 million tests |
Dimension (L*W*H) | 350 × 300 × 200 mm |
Weight | 4.5 kg |
Accessories No. | Name |
1 | Power cord |
2 | USB cable |
3 | Driving software |
4 | Color QC software |
5 | Black and white calibration tile |
The top port table top spectrophotometer can measure color of solid samples such as particles, powder, paste, pellets, opaque liquids used in textile, medicine, chemical, food, paper & other industries.