Benchtop Conductivity Meter LBCM-A14 Catalog

Benchtop Conductivity Meter LBCM-A14

Benchtop Conductivity Meter LBCM-A14

Overview

Benchtop Conductivity Meter LBCM-A14 with 1 to 3 points push button conductivity calibration, automatically recognizes calibration standards. With setup menu, it does setting of 6 parameters calibration points, temperature units and others. Large LCD display shows settings and measurement values. Temperature calibration by manual method improves the accuracy of conductivity meter.

Features

  • - Measures conductivity, TDS, Temperature of the liquids
    Automatic temperature compensation for accurate values over the entire range
    Selectable temperature units (°C or °F) for different application requirements
    Reset function automatically resumes all the setting back to factory default options
    Manual and automatic mode of temperature calibration
    Auto hold feature to lock, record and read stable measurement endpoint
    Stability indicator displays the status of current measurement
    Help message as an operational guide, with quick access to test parameters
    Conductivity/TDS Mode
    1 to 3 Conductivity push button calibration points
    3 TDS calibration points
    1 Temperature calibration point
Specifications
Conductivity Mode {"Conductivity measurement range":"0.01-20.0, 200.0, 2000 \u00b5S\/cm, 20.00, 200.0 mS\/cm","Conductivity accuracy":"\u00b11% F.S.","Conductivity resolution":"0.001, 0.01, 0.1, 1","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm , 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm"}
TDS Mode {"TDS measurement Range":"0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt)","TDS Accuracy":"\u00b1 1 % F.S.","TDS Factor":"0.01 to 1.00 (default 0.5)","TDS Calibration points":"3 points"}
Temperature Mode {"Temperature range":"0 to 105\u00b0C, 32 to 221\u00b0F","Temperature accuracy":"\u00b11\u00b0C","Temperature resolution":"0.1\u00b0C, 0.1\u00b0F","Temperature calibration points":"1 point","Temperature Compensation Range and Mode":"Manual or Automatic, 0 to 100\u00b0C , 32 to 212\u00b0F","Temperature coefficient":"0.0 to 10.0 % per \u00b0C"}
Cell constant K=0.1, 1, 10
Power requirements DC 9 V, using AC adapter, AC 220 V, 50 Hz
Dimension (L×W×H) 210 × 205 × 75 mm
Weight 1.5 kg
Standard Accessories :

Accessories no. Name
1 Conductivity Electrode (range 0.01 to 20 mS/ cm)
2 Temperature Probe
3 Conductivity Calibration Standard Solutions
4 Electrode Holder
5 Power Adapter

Optional Accessories :

Accessories no. Name
1 Conductivity Electrode (K=0.1) suitable for measuring the low conductivity liquids ( <10µS/ cm) e.g. Pure water
2 Conductivity Electrode (K=10) suitable for measuring the high conductivity liquids (>20mS/ cm) e.g. Sea water

Applications :

Used to test Conductivity, TDS values of different type of liquid such as pure, hard/low conductivity water, distilled water. Also used in water purification labs, water testing and management plants, and water processing and packaging units for quality and research purpose