Ask An Expert

Benchtop Ion meter for Cu, LBIM-A27 Catalog

Benchtop Ion meter for Cu, LBIM-A27

Benchtop Ion meter for Cu, LBIM-A27

Overview

Benchtop Ion meter for Cu, LBIM-A27 comes with (Cu) cupric ion selective electrode for cupric ion concentration measurement. This Ion meter comes with ± 1 % F.S. measurement accuracy. Its direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.

Features

  • - Large LCD display
    2 - 5 points calibration from low to high concentration
    Direct ion concentration readout for elaborate measurement process
    Selectable concentration units from ppm, mg / L, mol / L
    mV measurements to check the performance of ion selective electrode
    Temperature compensation provides accurate reading over the entire range
    Stability indicator to show current measurement status
    Calibration due reminder for regular calibration of the meter
    Auto hold function to freeze stable reading for better viewing & recording
    Automatic electrode diagnosis shows the slope of the sensor
    Reset setting function
    Expanded memory stores and recalls up to 500 readings
    Built –in real time clock stamps
    USB communication interface to transfer stored data to PC
Specifications
Ion measurement range Cu range: 1×108 - 1M, 0.06-6400 ppm
Ion measurement accuracy ± 1 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
mV range (-1999.9) to 1999.9 mV
mV accuracy ± 0.2 mV
mV resolution 0.1 mV
Temperature measurement range 0 to 105 °C, 32 to 221 °F
Temperature accuracy ± 0.5 °C, ± 0.9 °F
Temperature resolution 0.1°C
Temperature compensation 0 to 100 °C, 32 to 212 °F
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Power off Manual or automatic (10,20,30 minutes)
Memory Stores up to 500 sets of data
Output USB communication interface
Connector BNC
Display LCD (130 × 110 mm)
Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
Dimension (L × W × H) 210 × 188 × 60 mm
Weight 1.5 kg
Standard Accessories :

Cu Ion selective electrode
Temperature probe
Standard solution (1000 ppm)
Ionic strength adjuster (30 mL)
USB cable
DC 5 V Power adapter

Optional Accessories :

Ion selective electrode: Cu range: 1×108 - 1M, 0.06-6400 ppm
Ion standard solutions: 480 mL / bottle
Ionic strength adjuster: 480 mL / bottle
Temperature probe with sensor

Applications :

Benchtop Ion meter is used to measure the cupric ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.

Enquiry Now