Benchtop Multi-parameter Water Quality Meter LMPWM-A40 with 7 inch TFT display measures pH, mV, relative mV, water hardness, and temperature and Ion concentration of the sample. With expanded memory, it stores and recalls up to 1000 readings. Calibration due reminder informs operator to calibrate the meter regularly.
pH Mode |
|
||||||||||||
ORP Mode |
|
||||||||||||
mV Mode | |||||||||||||
Ion Mode |
|
||||||||||||
Water Hardness Mode |
|
||||||||||||
Temperature Mode |
|
||||||||||||
Conductivity Mode | |||||||||||||
TDS Mode | |||||||||||||
Salinity Mode | |||||||||||||
Resistivity Mode | |||||||||||||
Dissolved Oxygen Mode | |||||||||||||
Temperature Range | 0 to 100°C, 32 to 221°F | ||||||||||||
Temperature Accuracy | |||||||||||||
Temperature Resolution | |||||||||||||
Temperature Calibrations Points | |||||||||||||
Temperature Compensation Mode | Manual or Automatic | ||||||||||||
Data Hold Function | Manual or Automatic end point detection | ||||||||||||
Stability Criteria | Standard or high accuracy | ||||||||||||
Calibration Due Alarm | 1 to 31 days | ||||||||||||
Reset Function | Yes | ||||||||||||
Memory | Stores up to 1000 sets data | ||||||||||||
Output | USB communication interface | ||||||||||||
Connector | BNC Connector | ||||||||||||
Display | 7 inch TFT LCD display | ||||||||||||
Power supply | DC 12 V, AC adapter, AC 220 V, 50 Hz | ||||||||||||
Dimension (L × W × H) | 240 × 220 × 80 mm | ||||||||||||
Weight | 1.7 kg |
Accessories No. | Name |
1 | pH electrode |
2 | Temperature probe |
3 | pH buffer pouches (4.01/7.00/10.01) |
4 | Ion selective electrode |
5 | Ion calibration standard solution 100 and 1000 ppm |
6 | Water hardness electrode |
7 | Water hardness calibration solutions |
8 | Electrode holder |
9 | Power adapter |
Accessories No. | Name of the Ion electrode | Range |
1 | NH4 [Ammonium] Electrode | 5 × 10-6 ~1M |
2 | Br [Bromide] Electrode | 5 × 10-6 ~1M |
3 | Ca [Calcium] Electrode | 5 × 10-7 ~1M |
4 | Cl [Chloride] Electrode | 5 × 10-6 ~1M |
5 | Cn [Cyanide] Electrode | 5 × 10-6 ~0.01M |
6 | F [Fluoride] Electrode | 1 × 10-6 M~Saturation |
7 | NO3 [Nitrate] Electrode | 7 × 10-6 ~1M |
8 | Ag [Silver] Electrode | 1 × 10-7 ~1M |
9 | Na [Sodium[ Electrode | 1 × 10-5 ~1M |
10 | Cd [Cadmium] Electrode | 1 × 10-6 ~0.1M |
11 | Cu [Cupric] Electrode | 1 × 10-8 ~0.1M |
12 | I [Iodide] Electrode | 5 × 10-8 ~1M |
13 | Pb [Lead[ Electrode | 1 × 10-8 ~0.1M |
14 | K [Potassium] Electrode | 1 × 10-6 ~1M |
15 | S [Sulphide] Electrode | 1 × 10-7 ~1M |
16 | NH3 [Ammonia] Electrode | 1 × 10-6 ~1M |
Used in multi-parameters based research testing , and quality analysis of water, other general liquids across water plants, food and beverages production units, laboratories, and institutes.