Ask An Expert
Pocket Conductivity tester LPCT-A12 is equipped with platinum sensor & 1 point push button calibration system. The easy to use pocket conductivity meter comes with waterproof features design for protection against harsh conditions. Conductivity meter on the basis of its low, mid and high conductivity measurement range can be used for measuring conductivity of drinking water, waste water, brine water and liquids with high, low conductivity.
Conductivity measurement range | 0.1 to 19.99 mS/cm |
Type of conductivity | High range conductivity |
Conductivity accuracy | ± 1 % F.S. |
Conductivity calibration points | 1 point |
Conductivity calibration solutions | 12.88 mS/cm |
Sensor type | Platinum sensor |
Temperature compensation | 0 °C - 50 °C |
Temperature coefficient | 2 % per °C |
Cell constant | K=1 |
Normalization temperature | 25 °C |
Data hold function | Manual |
Display | LCD screen |
Power off | Manual or automatic (8 minutes after last key is pressed) |
Power | 3 × 1.5 V “G134” batteries |
Battery life | Approximately 150 hours |
Dimension (L*dia.) | 185 × 40 mm |
Weight | 100 g |
146.5 µS/cm, 1413 µS/cm, 12.88 mS/cm conductivity standard solutions
G134 batteries
Carrying box
84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm conductivity standard solutions
Platinum conductivity electrode
Pocket Conductivity tester on the basis of its low, mid and high conductivity measurement range can be used for testing conductivity of pure water, drinking water , waste water, brine solutions and liquids.