50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}, Ammonia nitrogen: {"Ammonia nitrogen determination range":"0.02 to 60 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}, Total phosphorous: {"Total phosphorous determination range":"0.002 to 20 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}. Dive into the product details to learn more. Visit labtron.cc for additional information!"> Multi parameter water quality analyzer LMWA-A10 Catalog | Labtron 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}, Ammonia nitrogen: {"Ammonia nitrogen determination range":"0.02 to 60 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}, Total phosphorous: {"Total phosphorous determination range":"0.002 to 20 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">

Ask An Expert

Multi parameter water quality analyzer LMWA-A10 Catalog

Multi parameter water quality analyzer LMWA-A10

Multi parameter water quality analyzer LMWA-A10

Overview

Multi parameter water quality analyzer LMWA-A10 with portable suitcase design, directly measures turbidity, chemical oxygen demand, ammonia and total phosphorous content of water sample, without any power supply. Incorporated with a 15 samples intelligent reactor, it meets the demand of user for testing large quantities of water samples. Its rated power of reactor is adjusted, according to the quantity of load.

Features

  • - Portable design
    Automatic switching for multi-parameters measurement
    15 samples intelligent reactor
    Pre storage for 113 standard curves
    Pre storage for 53 multi-point regression filling curves
    Intelligent data analysis
    Includes colorimetric, digestive system, timing system functions
    Built–in mini printer
    USB data interface
    User friendly operation
Specifications
CODCOD determination range: 2 to 10000 mg/ L
COD measurement accuracy: COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit: 0.1 mg/ L
COD measurement time: 20 minutes
COD repeatability: ≤ ± 5 %
Processing sample number per batch:
Consumables for colorimetric COD measurement: Colorimetric tubes and Cuvette
COD reactor digestion temperature: 165 ± 0.5°C
COD reactor digestion time: 10 min
COD reactor time setting switches: 3 pcs
Anti-chlorine interference: (Cl) < 1000 mg/ L No effect
Ammonia nitrogenAmmonia nitrogen determination range: 0.02 to 60 mg/ L
Ammonia nitrogen measurement accuracy: ≤ ± 10 %
Ammonia nitrogen minimum detection limit: 0.01 mg/ L
Ammonia nitrogen measurement time: 10 to 15 minutes
Ammonia nitrogen repeatability: ≤ ± 5 %
Processing sample number per batch:
Consumables for colorimetric ammonia nitrogen measurement: Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches: 3 pcs
Total phosphorousTotal phosphorous determination range: 0.002 to 20 mg/ L
Total phosphorous total phosphorous measurement accuracy: ≤ ± 5 %
Total phosphorous minimum detection limit: 0.001 mg/ L
Total phosphorous measurement time: 35 to 50 minutes
Total phosphorous repeatability: ≤ ± 5 %
Processing sample number per batch:
Consumables for colorimetric total phosphorous measurement: Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature: 120 ± 0.5°C
Total phosphorous reactor digestion time: 30 min
Total phosphorous reactor time setting switches: 3 pcs
TurbidityTurbidity determination range: 0.5 to 400 NTU
Turbidity measurement accuracy: ≤ ± 5 %
Turbidity minimum detection limit: 0.1 NTU
Turbidity measurement time: 1 minute
Turbidity repeatability: ≤ ± 5 %
Consumables for colorimetric turbidity measurement: Colorimetric Cuvette
Light source life100000 hours
Optical stability≤ 0.001 A/ 10 min
No. of curves166
Storage data12000
DisplayLCD (320 × 240)
InterfaceUSB
Power supplyAC 200 V
Dimension550 × 300 × 250 mm
Gross Weight21 kg
Standard Accessories :

Accessories no. Name
1 Protective cover
2 Cooling rack
3 Cuvette rack
4 Tube rack
5 Reagent proportional
6 Printing paper

Applications :

Used in on-field water quality analysis based on COD, ammonia nitrogen, total phosphorous and turbidity parameters.