50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}, Ammonia nitrogen: {"Ammonia nitrogen determination range":"0.02 to 60 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}, Total phosphorous: {"Total phosphorous determination range":"0.002 to 20 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">
Ask An Expert
Multi parameter water quality analyzer LMWA-A10 with portable suitcase design, directly measures turbidity, chemical oxygen demand, ammonia and total phosphorous content of water sample, without any power supply. Incorporated with a 15 samples intelligent reactor, it meets the demand of user for testing large quantities of water samples. Its rated power of reactor is adjusted, according to the quantity of load.
COD | COD determination range: 2 to 10000 mg/ L COD measurement accuracy: COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 % COD minimum detection limit: 0.1 mg/ L COD measurement time: 20 minutes COD repeatability: ≤ ± 5 % Processing sample number per batch: Consumables for colorimetric COD measurement: Colorimetric tubes and Cuvette COD reactor digestion temperature: 165 ± 0.5°C COD reactor digestion time: 10 min COD reactor time setting switches: 3 pcs Anti-chlorine interference: (Cl) < 1000 mg/ L No effect |
Ammonia nitrogen | Ammonia nitrogen determination range: 0.02 to 60 mg/ L Ammonia nitrogen measurement accuracy: ≤ ± 10 % Ammonia nitrogen minimum detection limit: 0.01 mg/ L Ammonia nitrogen measurement time: 10 to 15 minutes Ammonia nitrogen repeatability: ≤ ± 5 % Processing sample number per batch: Consumables for colorimetric ammonia nitrogen measurement: Colorimetric tubes and Cuvette Ammonia nitrogen reactor time setting switches: 3 pcs |
Total phosphorous | Total phosphorous determination range: 0.002 to 20 mg/ L Total phosphorous total phosphorous measurement accuracy: ≤ ± 5 % Total phosphorous minimum detection limit: 0.001 mg/ L Total phosphorous measurement time: 35 to 50 minutes Total phosphorous repeatability: ≤ ± 5 % Processing sample number per batch: Consumables for colorimetric total phosphorous measurement: Colorimetric tubes and Cuvette Total phosphorous reactor digestion temperature: 120 ± 0.5°C Total phosphorous reactor digestion time: 30 min Total phosphorous reactor time setting switches: 3 pcs |
Turbidity | Turbidity determination range: 0.5 to 400 NTU Turbidity measurement accuracy: ≤ ± 5 % Turbidity minimum detection limit: 0.1 NTU Turbidity measurement time: 1 minute Turbidity repeatability: ≤ ± 5 % Consumables for colorimetric turbidity measurement: Colorimetric Cuvette |
Light source life | 100000 hours |
Optical stability | ≤ 0.001 A/ 10 min |
No. of curves | 166 |
Storage data | 12000 |
Display | LCD (320 × 240) |
Interface | USB |
Power supply | AC 200 V |
Dimension | 550 × 300 × 250 mm |
Gross Weight | 21 kg |
Accessories no. | Name |
1 | Protective cover |
2 | Cooling rack |
3 | Cuvette rack |
4 | Tube rack |
5 | Reagent proportional |
6 | Printing paper |
Used in on-field water quality analysis based on COD, ammonia nitrogen, total phosphorous and turbidity parameters.