50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}, Ammonia nitrogen: {"Ammonia nitrogen determination range":"0.02 to 30 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"20 pcs","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}, Total phosphorous: {"Total phosphorous determination range":"0.002 to 10 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}. Dive into the product details to learn more. Visit labtron.cc for additional information!"> Multi parameter water quality analyzer LMWA-A11 Catalog | Labtron 50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}, Ammonia nitrogen: {"Ammonia nitrogen determination range":"0.02 to 30 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"20 pcs","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}, Total phosphorous: {"Total phosphorous determination range":"0.002 to 10 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">

Ask An Expert

Multi parameter water quality analyzer LMWA-A11 Catalog

Multi parameter water quality analyzer LMWA-A11

Multi parameter water quality analyzer LMWA-A11

Overview

Multi parameter water quality analyzer LMWA-A11 is a high quality analyzer with benchtop design, simultaneously measures turbidity, chemical oxygen demand, ammonia and total phosphorous content of water sample. The aviation insulation protective layer present above digestion hole, effectively prevents scalds. The imported heat resistant protective cover ensures the safety and reliability of the experiment.

Features

  • - Benchtop design
    High definition LCD screen with detailed user interface
    Includes colorimetric, digestive system, timing system functions
    Intelligent data analysis
    USB infrared data communication
    Built-in mini printer
    High accuracy measurement readings
    User-friendly operation
Specifications
CODCOD determination range: 5 to 5000 mg/ L
COD measurement accuracy: COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 %
COD minimum detection limit: 0.1 mg/ L
COD measurement time: 20 minutes
COD repeatability: ≤ ± 5 %
Processing sample number per batch: 12 pcs
Consumables for colorimetric COD measurement: Colorimetric tubes and Cuvette
COD reactor digestion temperature: 165 ± 0.5°C
COD reactor digestion time: 10 min
COD reactor time setting switches: 3 pcs
Anti-chlorine interference: (Cl) < 1000 mg/ L No effect
Ammonia nitrogenAmmonia nitrogen determination range: 0.02 to 30 mg/ L
Ammonia nitrogen measurement accuracy: ≤ ± 10 %
Ammonia nitrogen minimum detection limit: 0.01 mg/ L
Ammonia nitrogen measurement time: 10 to 15 minutes
Ammonia nitrogen repeatability: ≤ ± 5 %
Processing sample number per batch: 20 pcs
Consumables for colorimetric ammonia nitrogen measurement: Colorimetric tubes and Cuvette
Ammonia nitrogen reactor time setting switches: 3 pcs
Total phosphorousTotal phosphorous determination range: 0.002 to 10 mg/ L
Total phosphorous total phosphorous measurement accuracy: ≤ ± 5 %
Total phosphorous minimum detection limit: 0.001 mg/ L
Total phosphorous measurement time: 35 to 50 minutes
Total phosphorous repeatability: ≤ ± 5 %
Processing sample number per batch: 12 pcs
Consumables for colorimetric total phosphorous measurement: Colorimetric tubes and Cuvette
Total phosphorous reactor digestion temperature: 120 ± 0.5°C
Total phosphorous reactor digestion time: 30 min
Total phosphorous reactor time setting switches: 3 pcs
TurbidityTurbidity determination range: 0.5 to 400 NTU
Turbidity measurement accuracy: ≤ ± 5 %
Turbidity minimum detection limit: 0.1 NTU
Turbidity measurement time: 1 minute
Turbidity repeatability: ≤ ± 5 %
Consumables for colorimetric turbidity measurement: Colorimetric Cuvette
Light source life100000 hours
Optical stability≤ 0.001 A/ 10 min
No. of curves56
Storage data12000
DisplayLCD (320 × 240)
InterfaceUSB
Power supplyAC 200 V
Dimension450 × 300 × 250 mm
Gross Weight18 kg
Standard Accessories :

Accessories no. Name
1 Protective cover
2 Cooling rack
3 Cuvette rack
4 Tube rack
5 Reagent proportional
6 Printing paper

Applications :

Used in water quality testing based on COD, ammonia nitrogen, total phosphorous and turbidity parameters across plants, laboratories, and industries.

Enquiry Now