50 mg\/ L, \u2264 \u00b1 5 %","COD minimum detection limit":"0.1 mg\/ L","COD measurement time":"20 minutes","COD repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric COD measurement":"Colorimetric tubes and Cuvette","COD reactor digestion temperature":"165 \u00b1 0.5\u00b0C","COD reactor digestion time":"10 min","COD reactor time setting switches":"3 pcs","Anti-chlorine interference":"(Cl) < 1000 mg\/ L No effect"}, Ammonia nitrogen: {"Ammonia nitrogen determination range":"0.02 to 30 mg\/ L","Ammonia nitrogen measurement accuracy":"\u2264 \u00b1 10 %","Ammonia nitrogen minimum detection limit":"0.01 mg\/ L","Ammonia nitrogen measurement time":"10 to 15 minutes","Ammonia nitrogen repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"20 pcs","Consumables for colorimetric ammonia nitrogen measurement":"Colorimetric tubes and Cuvette","Ammonia nitrogen reactor time setting switches":"3 pcs"}, Total phosphorous: {"Total phosphorous determination range":"0.002 to 10 mg\/ L","Total phosphorous total phosphorous measurement accuracy":"\u2264 \u00b1 5 %","Total phosphorous minimum detection limit":"0.001 mg\/ L","Total phosphorous measurement time":"35 to 50 minutes","Total phosphorous repeatability":"\u2264 \u00b1 5 %","Processing sample number per\ufeff\ufeff\u00a0batch":"12 pcs","Consumables for colorimetric total phosphorous measurement":"Colorimetric tubes and Cuvette","Total phosphorous reactor digestion temperature":"120 \u00b1 0.5\u00b0C","Total phosphorous reactor digestion time":"30 min","Total phosphorous reactor time setting switches":"3 pcs"}. Dive into the product details to learn more. Visit labtron.cc for additional information!">
Ask An Expert
Multi parameter water quality analyzer LMWA-A11 is a high quality analyzer with benchtop design, simultaneously measures turbidity, chemical oxygen demand, ammonia and total phosphorous content of water sample. The aviation insulation protective layer present above digestion hole, effectively prevents scalds. The imported heat resistant protective cover ensures the safety and reliability of the experiment.
COD | COD determination range: 5 to 5000 mg/ L COD measurement accuracy: COD < 50 mg/ L, ≤ ± 10 % and COD > 50 mg/ L, ≤ ± 5 % COD minimum detection limit: 0.1 mg/ L COD measurement time: 20 minutes COD repeatability: ≤ ± 5 % Processing sample number per batch: 12 pcs Consumables for colorimetric COD measurement: Colorimetric tubes and Cuvette COD reactor digestion temperature: 165 ± 0.5°C COD reactor digestion time: 10 min COD reactor time setting switches: 3 pcs Anti-chlorine interference: (Cl) < 1000 mg/ L No effect |
Ammonia nitrogen | Ammonia nitrogen determination range: 0.02 to 30 mg/ L Ammonia nitrogen measurement accuracy: ≤ ± 10 % Ammonia nitrogen minimum detection limit: 0.01 mg/ L Ammonia nitrogen measurement time: 10 to 15 minutes Ammonia nitrogen repeatability: ≤ ± 5 % Processing sample number per batch: 20 pcs Consumables for colorimetric ammonia nitrogen measurement: Colorimetric tubes and Cuvette Ammonia nitrogen reactor time setting switches: 3 pcs |
Total phosphorous | Total phosphorous determination range: 0.002 to 10 mg/ L Total phosphorous total phosphorous measurement accuracy: ≤ ± 5 % Total phosphorous minimum detection limit: 0.001 mg/ L Total phosphorous measurement time: 35 to 50 minutes Total phosphorous repeatability: ≤ ± 5 % Processing sample number per batch: 12 pcs Consumables for colorimetric total phosphorous measurement: Colorimetric tubes and Cuvette Total phosphorous reactor digestion temperature: 120 ± 0.5°C Total phosphorous reactor digestion time: 30 min Total phosphorous reactor time setting switches: 3 pcs |
Turbidity | Turbidity determination range: 0.5 to 400 NTU Turbidity measurement accuracy: ≤ ± 5 % Turbidity minimum detection limit: 0.1 NTU Turbidity measurement time: 1 minute Turbidity repeatability: ≤ ± 5 % Consumables for colorimetric turbidity measurement: Colorimetric Cuvette |
Light source life | 100000 hours |
Optical stability | ≤ 0.001 A/ 10 min |
No. of curves | 56 |
Storage data | 12000 |
Display | LCD (320 × 240) |
Interface | USB |
Power supply | AC 200 V |
Dimension | 450 × 300 × 250 mm |
Gross Weight | 18 kg |
Accessories no. | Name |
1 | Protective cover |
2 | Cooling rack |
3 | Cuvette rack |
4 | Tube rack |
5 | Reagent proportional |
6 | Printing paper |
Used in water quality testing based on COD, ammonia nitrogen, total phosphorous and turbidity parameters across plants, laboratories, and industries.