Ask An Expert

Portable Conductivity Meter LPCM-A10 Catalog

Portable Conductivity Meter LPCM-A10

Portable Conductivity Meter LPCM-A10

Overview

Portable Conductivity Meter LPCM-A10 is adapted for measuring quality of water on parameter such as conductivity and TDS. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing and for research purpose. It is reliable and user friendly.

Features

  • - Common features
    Calibration due reminder informs operator to calibrate the meter regularly
    Stability indicator displays the status of current measurement
    Auto hold function freezes stable, final readings for better viewing and recording
    1 to 3 points push button calibration to automatically identify calibration solutions
    Selectable temperature units (°C or °F) for different application requirements
    Expanded memory stores and recalls up to 500 readings
    Calibration report provides details of calibration standard and cell constant
    Help message as an operational guide, helps users for quick access to the parameters
    Reset function automatically resumes all settings back to factory default options
    Store data is transferrable into computer via USB communication interface
    Conductivity / Temperature
    Conductivity: 1 to 3 point calibration with automatically identification of calibration solutions
    Temperature: Can select cell constant (0.1/1/10) and normalization temperature 25°C
    Linear compensation improves the measurement accuracy
Specifications
Conductivity {"Conductivity measurement range":"0.01 to 20.00, 200.0, 2000 \u00b5S\/cm, 20.00, 200 mS\/cm","Conductivity accuracy":"\u00b10.5% F.S","Conductivity calibration points":"1 to 3 points","Conductivity calibration solutions":"10 \u00b5S\/cm, 84 \u00b5S\/cm, 1413 \u00b5S\/cm, 12.88 mS\/cm, 111.8 mS\/cm or Custom","Conductivity resolution":"0.001, 0.01, 0.1, 1"}
Temperature {"Temperature measuring range":"0 105 \u00b0C, 32 to 221 \u00b0F","Temperature measuring accuracy":"\u00b1 \u00b00.5 C, \u00b1 0.9 \u00b0F","Temperature calibration points":"1 point","Temperature resolution":"0.1 \u00b0C, 0.1 \u00b0F"}
Temperature compensation 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient Linear
Reference temperature 25 °C
Stability conditions Low or high
Cell constant K= 0.1, 1, 10 or custom
Calibration due 1 to 31 days or off
Memory 100 data sets
Data hold Manual or auto-end point
Connector 6 pin mini plug
Power Control Manual or Automatic (10, 20 or 30 minutes after last key pressed)
Power 3 × 1.5 V AA batteries or DC 5 V power adapter
Dimension (L × W × H) 170 × 85 × 30 mm
Weight 300 g
Standard Accessories :

Number of accessories Accessories name
1 Conductivity electrode (range: 10 µS/cm to 10 mS/cm)
2 Temperature probe
3 Standard calibration solutions (84 µS/cm, 1413 µS/cm, 12.88 mS/cm)
4 Carrying case

Optional Accessories :

Number of accessories Accessories name
1 Conductivity electrode for general application
2 Conductivity electrode (K= 0.1): Suitable for measuring the low conductivity liquids ( <10 µS/cm ) for pure water
3 Conductivity electrode (K= 10): Suitable for measuring the high conductivity liquids ( >20 mS/cm ) for sea water

Applications :

Used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.

Enquiry Now