Portable Conductivity Meter LPCM-A13 is adapted with different modes for measuring quality of water on parameters such as conductivity, total dissolved solids, salinity, resistivity and temperature. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing and for research purpose. It is reliable and user friendly.
Conductivity | Conductivity measurement range: 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200 mS/cm Conductivity accuracy: ±0.5% F.S Conductivity calibration points: 1 to 5 points Conductivity calibration solutions: 10 µS/cm, 84 µS/cm, 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm or Custom Conductivity resolution: 0.001, 0.01, 0.1, 1 |
TDS | TDS range: 0 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) TDS accuracy: ±1 % F.S TDS factor: 0.01 to 1.00 (Default 0.5) TDS resolution: 0.01, 0.1, 1 |
Salinity | Salinity range: 0.00 to 80.00 ppt, 0.00 to 42.00 psu Salinity accuracy: ±1% F.S Salinity measurement modes: Practical Salinity (psu) or Natural Seawater (ppt) Salinity resolution: 0.01, 0.1, 1 |
Resistivity | Resistivity range: 0.00 to 20 MΩ Resistivity accuracy: ±1% F.S Resistivity resolution: 0.01, 0.1, 1 |
Temperature | Temperature measuring range: 0 105 °C, 32 to 221 °F Temperature measuring accuracy: ± °0.5 C, ± 0.9 °F Temperature calibration points: 1 point Temperature resolution: 0.1 °C, 0.1 °F |
Temperature compensation | 0 to 100 °C, 32 to 212 ° F, Manual or Automatic |
Temperature coefficient | Linear and Pure water compensation |
Reference temperature | 20 °C or 25 °C |
Stability conditions | Low or high |
Cell constant | K= 0.1, 1, 10 or custom |
Calibration due | 1 to 31 days or off |
Memory | 500 data sets |
Data hold | Manual or auto-end point |
Connector | 6 pin mini plug |
Power Control | Manual or Automatic (10, 20 or 30 minutes after last key pressed) |
Power | 3 × 1.5 V AA batteries or DC 5 V power adapter |
Dimension (L × W × H) | 170 × 85 × 30 mm |
Weight | 300 g |
Number of accessories | Accessories name |
1 | Conductivity electrode (range: 10 µS/cm to 10 mS/cm) |
2 | Temperature probe |
3 | Standard calibration solutions (84 µS/cm, 1413 µS/cm, 12.88 mS/cm) |
4 | Carrying case |
Number of accessories | Accessories name |
1 | Conductivity electrode for general application |
2 | Conductivity electrode (K= 0.1): Suitable for measuring the low conductivity liquids ( <10 µS/cm ) for pure water |
3 | Conductivity electrode (K= 10): Suitable for measuring the high conductivity liquids ( >20 mS/cm ) for sea water |
Used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.