Ask An Expert

Portable Multi-parameter Water Quality Meter LMPWM-A10 Catalog

Portable Multi-parameter Water Quality Meter LMPWM-A10

Portable Multi-parameter Water Quality Meter LMPWM-A10

Overview

Portable Multi-parameter Water Quality Meter LMPWM-A10 is adapted with different modes for measuring quality of water on different parameters such as pH, ORP, Ion, conductivity, TDS, salinity, dissolved oxygen content. Due to its portable design, it is suitable for outdoor measurements i.e. on site water testing, remote area water testing & for research purpose. It is reliable and user friendly.

Features

  • - Common Features Calibration due reminder informs operator to calibrate the meter regularly
    Stability indicator displays the status of current measurement
    Auto hold function freezes stable, final readings for better viewing and recording
    Manual temperature calibration to rectify the deviations in temperature
    Automatic temperature compensation for accurate measured value over the entire range
    Selectable temperature units (°C or °F) for different application requirements
    Expanded memory stores and records up to 500 readings
    Help message as an operational guide, helps users for quick access to the parameters
    Reset function automatically resumes all the setting back to factory default options
    Store data is transferrable into computer via USB communication interface
    pH mode 1-5 points push button calibration to automatically identify pH buffer
    Convenient to select pH buffer standard (USA/NIST/DIN) or custom
    Automatic electrode slope display helps operator whether to replace the sensor
    ORP mode 1 point offset calibration to adjust the display value to known standard
    Relative & absolute mV measurements for accurate ORP readings
    Ion concentration mode 2-5 points calibration, included with 8 concentration points for selection
    Automatic recognition of ion electrodes, no need to specify type of ion
    mV measurements mode for checking the performance of current ion electrode
    Direct reading of concentration measurements to avoid critical conversation and calculations
    Multiple concentration units to be suitable for various applications
    Conductivity / TDS / Salinity / Resistivity Mode 1-5 point for calibration with automatically identification of calibration solutions
    Can select cell constant (0.1/1/10) and normalization temperature (20°C or 25°C)
    TDS conversion factor, seawater, practical salinity measurements mode to meet different water quality measurement requirements
    Linear or pure water compensation improves the measurement accuracy
    Dissolved oxygen mode 1-2 points calibration using the air-sealed water & zero oxygen solution
    Manual salinity & barometric pressure compensation for accurate readings
Specifications
pH modepH measurement range: (-2.000) to 20.000 pH
pH accuracy: ± 0.002 pH
pH calibration points: 1 - 5 points
pH calibration solutions: USA, NIST, DIN or user defined
ORP measurementORP measurement range: -1999.9 to 1999.9 mV
ORP accuracy: ±0.2 mV
ORP calibration points: 1 point
ORP calibration solutions: mV & relative mV
Ion measurementIon measurement range: 0 to 19999 ppm, mg/L, mol/L
Ion accuracy: ± 0.5 % F.S. (monovalent), ± 1 % F.S. (divalent)
Ion calibration points: 2 - 5 points
Ion calibration solutions: 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol/L, mg/L
Conductivity measurementConductivity measurement range: 0 - 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm
Conductivity accuracy: ± 0.5 % F.S.
Conductivity calibration points: 1 - 5 points
Conductivity calibration solutions: 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm
Temperature coefficient: 0.0 to 10.0 % / °C
Compensation modes: Linear or pre water
Cell constant: K = 0.1, 1, 10 or user-defined
Normalization temperature: 20 °C or 25 °C
TDS measurementTDS range: 0 to 100 ppt. (max. 200 ppt., depending on factor setting)
TDS accuracy: ± 1 % F.S.
TDS factor: 0.1 - 1.0 (default 0.5)
Salinity measurementSalinity range: 0 to 100 ppt. (max. 80 ppt.)
Salinity accuracy: ± 1 % F.S
Measurement modes: Seawater or practical salinity
ResistivityResistivity range: 0 to 100 Ω
Resistivity accuracy: ± 1 % F.S
Resistivity resolution: 0.01, 0.1, 1
Dissolved oxygenDO concentration range: 0.00 to 20.00 mg/L
DO accuracy: ± 0.2 mg/L
Calibration points: 1 - 2 points
Pressure correction: 60.0 to 112.5 kPa, 450 - 850 mmHg
Salinity correction: 0 to 50 g/L
% Saturation of Oxygen: 0.0 to 200.0 %
Accuracy: ± 2.0 %
Temperature compensation0 to 100 °C, 32 to 212 °F, Manual or Automatic
Stability conditionsLow or high
Calibration due0 to 31 days
MemoryStores up to 500 data sets
OutputUSB communication interface
Connector
Display
Dimension (L × W × H)185 × 88 × 32 mm
Weight300 g
Power supply3 × 1.5 V “AA batteries or DC 5 V power adapter
Standard Accessories :

pH, conductivity & dissolved oxygen electrodes
PH and conductivity electrodes
pH and dissolved oxygen electrodes
conductivity and dissolved oxygen electrodes

Optional Accessories :

Temperature probe
Calibration solutions
Batteries
Carrying case

Applications :

The portable multi-parameter water quality meter is used for quality testing of water on different parameters in research and development labs, water resources and plants in nearby or remote area.

Enquiry Now