Column heater: | {"Operating temperature range":"Room temperature 20 to 60\u00b0C ( 68 to 140\u00b0F)","Controlling temperature accuracy":"\u00b1 0.01\u00b0C","Allowable deviation of column heater temperature":"\u00b1 2\u00b0C","Temperature stability":"\u2264 1\u00b0C\/ h"} |
Degassing device: | {"Type":"Built-in low pressure","Vacuum degree":"(-) 70 kPa","Maximum flow rate":"10 ml\/ min","Internal volume":"30 \u00b5l","Degassing efficiency":"10 ml\/ min 90 %"} |
Digital temperature and control detection system: | {"Type":"Temperature-control and Bipolar conductivity detector","Detection mode":"Bipolar conductivity detection","Cell volume":"\u2264 0.8 \u00b5l","Detection range":"0 to 50000 \u00b5S\/ cm","Output voltage":"-6000 to +6000 mV (adjustable)","Operating temperature":"Room temperature 5 to 60\u00b0C ( 41 to 140\u00b0F)","Controlling temperature accuracy":"\u00b1 0.01\u00b0C","Maximum pressure":"10 MPa","Linear range":"\u2265 103","Instrument linearity":"\u2265 0.999","Quantitative repeatability":"\u2264 1.0 %","Qualitative repeatability":"\u2264 1.0 %"} |
Eluent generator: | {"Eluent type":"KOH\/ NaOH","Eluent concentration range":"0.1 to 100 mM","Concentration increment":"0.1 mM","Flow rate change":"0.1 to 3.0 ml\/ min","Maximum pressure":"20 MPa","Minimum pressure":"5 MPa"} |
Built-in Eluent Generator: | {"Eluent types":"KOH\/ NaOH","Eluent concentration range":"0.1 to 100 mM","Concentration increment":"0.1 mM","Flow rate change":"0.1 to 3.0 ml\/ min","Maximum pressure":"20 MPa","Minimum pressure":"5 MPa"} |
Conductivity detector: | {"Type":"Temperature Control and Bipolar Conductivity Detector","Detection mode":"Bipolar conductivity detection","Cell volume":"\u2264 0.8 \u00b5L","Detection range":"0 to 35000 \u00b5S\/ cm","Detection resolution":"\u2264 0.0020 nS\/ cm","Output voltage":"- 6000 to +6000 mV (adjustable)","Baseline noise":"\u2264 0.05 % F.S.","Baseline drift":"\u2264 3 % FS\/ 30 min","Operating temperature range":"Room temperature +5 to 60\u00b0C (41 to 140\u00b0F)","Controlling temperature accuracy":"\u00b1 0.01\u00b0C","Maximum pressure":"10 MPa","Linear range":"\u2265 103","Instruments linearity":"\u2265 0.999","Quantitative repeatability":"\u2264 1.0 %","Qualitative repeatability":"\u2264 1.0 %","Minimum detectable concentration":"Cl \u2264 0.0005 ug\/ ml \nBrO3 \u2264 0.001 ug\/ ml \nLi+ \u2264 0.001 ug\/ ml"} |
Degassing Device: | {"Inner volume":"300 \u00b5l","Degassing volume":"7.5 ml","Maximum flow rate":"10 ml\/ min","Degassing efficiency":"Degassing 90 % at 1ml\/ min","Organic tolerance":"1"} |
External dimension: | 350 × 470 × 650 mm |
Conductivity detector: | {"Type":"Temperature Control and Bipolar Conductivity Detector","Detection mode":"Bipolar conductivity detection","Cell volume":"\u2264 0.8 \u00b5L","Detection range":"0 to 45000 \u00b5S\/ cm","Detection resolution":"\u2264 0.0020 nS\/ cm","Output voltage":"- 6000 to +6000 mV (adjustable)","Baseline noise":"\u2264 0.05 % F.S.","Baseline drift":"\u2264 3 % FS\/ 30 min","Operating temperature range":"Room temperature +5 to 60\u00b0C (41 to 140\u00b0F)","Controlling temperature accuracy":"\u00b1 0.01\u00b0C","Maximum pressure":"10 MPa","Linear range":"\u2265 103","Instruments linearity":"\u2265 0.999","Quantitative repeatability":"\u2264 1.0 %","Qualitative repeatability":"\u2264 1.0 %","Minimum detectable concentration":"Cl \u2264 0.0005 ug\/ ml \nBrO3 \u2264 0.001 ug\/ ml \nLi+ \u2264 0.001 ug\/ ml"} |
External dimension: | 350 × 470 × 510 mm |
Flow system: | {"Plastic flow path":"Made of PEEK materials","Six way Valve":"PEEK material, 5000 psi pressure, independent automatic collection and flow function"} |
Gross weight: | 32 kg |