Ask An Expert

Pocket TDS tester LPTS-A12

Pocket TDS tester LPTS-A12 is equipped with platinum sensor & 1 point push button calibration system. It comes with high TDS measurement range. It is easy to use & with waterproof features design it provides protection against harsh conditions. The standard platinum sensor provides fast and reliable measuring results. Total dissolved solid content present in drinking water, waste water, swimming pool & aquarium water can be measured using pocket TDS meter.

Pocket TDS tester LPTS-A12

TDS range 0.05 - 10.00 ppt
TDS accuracy ± 1 % F.S.
TDS factor 0.4 to 1.0 (default 0.5)
Calibration points 1 point
TDS type range High range TDS
Calibration solutions 7447 ppm
Type of sensor Platinum sensor
Temperature compensation 0 °C - 50 °C, Automatic
Temperature coefficient 2 % per °C
Normalization temperature 25 °C
Operating temperature 0 °C - 60 °C, 32 °F - 140 °F
Connector 6 pin
Display LCD screen
Data hold function Manual
Battery life Approximately 150 hours
Power off Manual or automatic (8 minutes after last key is pressed)
Power 3 × 1.5 V “G13A”
Dimension (L × dia.) 185 × 40 mm
Weight 100 g

  • Selectable TDS conversion factor for accurate measurements
    1 point push button calibration to adjust the display value to known standard
    Equipped with platinum sensor
    High TDS measurement range
    Automatic temperature compensation for accurate measured value over the entire range
    Auto hold function freezes stable, final readings for better viewing and recording
    Automatic power off helps to reduce battery power consumption
    Waterproof features guarantees protection against harsh conditions
    Replaceable electrode module to reduce the maintenance , replacement cost

Pocket TDS tester is used to measure TDS content in waste water, swimming pool & aquarium, pure water, drinking water. It is also used in educational and other industrial applications for TDS measurement from test samples.

pH Meter (Benchtop)

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Conductivity Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Dissolved Oxygen Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Ion Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Benchtop Water Hardness Meter

Labtron benchtop meters are easy to use. The LCD display, manual or automatic mode of calibration, universal connector and other features are included in this range to produce accurate, reliable results. It consist of benchtop meter for measuring pH, conductivity, dissolved oxygen content, Ion concentration, water hardness level. These meters are suitable for simple to complex applications in water quality testing, research and analysis etc.

Conductivity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Dissolved Oxygen Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

ORP Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

pH Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.

Salinity Tester

Labtron pocket testers are small and compact in size, gives fast and accurate results. The Pocket testers consist of pH, ORP, TDS, dissolved oxygen, salinity and conductivity tester for various laboratory as well as outdoor applications. Measurements can be taken by inserting the probe in to the test solution and after gentle stirring, stable readings can be noted down.