| Ion Chromatographic pump: | {"Type":"High pressure and low pulse double plunger tandem advection pump","Maximum pressure":"35 MPa (PEEK)","Display pressure accuracy":"\u2264 0.1 MPa","Flow stability":"(0.2 to 0.5) ml\/ min \u2264 3 % , (0.5 to 1.0) ml\/ min \u2264 2 %, > 1.0 ml\/ min \u2264 2 %","Flow range":"0.001 to 9.999 ml\/ min","Pressure pulse":"\u2264 0.5 %"} |
| Numerical control and electromagnetic injection: | {"Maximum pressure":"35 MPa","Contact material of the rotor":"PEEK","Control mode":"By Stepper motor","Power supply":"DC 24 V"} |
| Column heater: | {"Operating temperature range":"Room temperature 20 to 60\u00b0C ( 68 to 140\u00b0F)","Controlling temperature accuracy":"\u00b1 0.01\u00b0C","Allowable deviation of column heater temperature":"\u00b1 2\u00b0C","Temperature stability":"\u2264 1\u00b0C\/ h"} |
| Flow system: | {"Plastic flow path":"Made up of PEEK material","Six way valve":"PEEK material pressure 5000 psi, independent automatic collection and flow function"} |
| Ion Chromatographic Pump: |
{"Type":"High pressure and low pulse double plunger tandem advection pump","Maximum pressure":"35 MPa (PEEK)","Pressure display accuracy":"\u2264 0.1 MPa","Flow stability":"(0.2 to 0.5) ml\/ min \u2264 3 % \n(0.5 to 1.0) ml\/ min \u2264 2 % \n> 1.0 ml\/ min 2 % ","Flow range":"0.001 to 9.999 ml\/ min","Pressure pulse":"\u2264 0.5%"} |
| Conductivity detector: |
{"Type":"Temperature Control and Bipolar Conductivity Detector","Detection mode":"Bipolar conductivity detection","Cell volume":"\u2264 0.8 \u00b5L","Detection range":"0 to 35000 \u00b5S\/ cm","Detection resolution":"\u2264 0.0020 nS\/ cm","Output voltage":"- 6000 to +6000 mV (adjustable)","Baseline noise":"\u2264 0.05 % F.S.","Baseline drift":"\u2264 3 % FS\/ 30 min","Operating temperature range":"Room temperature +5 to 60\u00b0C (41 to 140\u00b0F)","Controlling temperature accuracy":"\u00b1 0.01\u00b0C","Maximum pressure":"10 MPa","Linear range":"\u2265 103","Instruments linearity":"\u2265 0.999","Quantitative repeatability":"\u2264 1.0 %","Qualitative repeatability":"\u2264 1.0 %","Minimum detectable concentration":"Cl \u2264 0.0005 ug\/ ml \nBrO3 \u2264 0.001 ug\/ ml \nLi+ \u2264 0.001 ug\/ ml"} |
| Flow system: | {"Plastic flow path":"Made of PEEK materials","Six way Valve":"PEEK material, 5000 psi pressure, independent automatic collection and flow function"} |
| Degassing Device: | {"Inner volume":"300 \u00b5l","Degassing volume":"7.5 ml","Maximum flow rate":"10 ml\/ min","Degassing efficiency":"Degassing 90 % at 1ml\/ min","Organic tolerance":"1"} |
| Ion Chromatographic Pump: |
{"Type":"High pressure and low pulse double plunger tandem advection pump","Maximum pressure":"35 MPa (PEEK)","Pressure display accuracy":"\u2264 0.1 MPa","Flow stability":"(0.2 to 0.5) ml\/ min \u2264 3 % \n(0.5 to 1.0) ml\/ min \u2264 2 % \n> 1.0 ml\/ min 2 %","Flow range":"0.001 to 9.999 ml\/ min","Pressure pulse":"\u2264 0.5%"} |
| Conductivity detector: |
{"Type":"Temperature Control and Bipolar Conductivity Detector","Detection mode":"Bipolar conductivity detection","Cell volume":"\u2264 0.8 \u00b5L","Detection range":"0 to 45000 \u00b5S\/ cm","Detection resolution":"\u2264 0.0020 nS\/ cm","Output voltage":"- 6000 to +6000 mV (adjustable)","Baseline noise":"\u2264 0.05 % F.S.","Baseline drift":"\u2264 3 % FS\/ 30 min","Operating temperature range":"Room temperature +5 to 60\u00b0C (41 to 140\u00b0F)","Controlling temperature accuracy":"\u00b1 0.01\u00b0C","Maximum pressure":"10 MPa","Linear range":"\u2265 103","Instruments linearity":"\u2265 0.999","Quantitative repeatability":"\u2264 1.0 %","Qualitative repeatability":"\u2264 1.0 %","Minimum detectable concentration":"Cl \u2264 0.0005 ug\/ ml \nBrO3 \u2264 0.001 ug\/ ml \nLi+ \u2264 0.001 ug\/ ml"} |
| Flow system: | {"Plastic flow path":"Made of PEEK materials","Six way Valve":"PEEK material, 5000 psi pressure, independent automatic collection and flow function"} |
| Power supply: | 150 W |