Portable 10 in 1 Multi Gas Detector LMGD-A10 is simultaneous detector of 10 gases namely O2, CH4, CO2, VOC, CO, H2S, SO2, CL2, NO2, NH3. It display multiple display modes selectable, multi-channel data mode, multi-curve mode, multi-channel data + multi- curve mode and single channel + single curve mode. Designed with 3.5-inch high-definition color screen, high resolution, wide viewing angle. The air supply system of up to three pumps can switch the pump arbitrarily, blocking the loss of the cross-gas to the relevant sensor and prolonging the service life of the sensor. It support gas concentration data display, gas concentration real-time curve display mode arbitrary switching.
Portable 10 in 1 Multi Gas Detector is used in pharmaceutical, medical, food, corrosion, Disinfection, chemical fertilizers, resins, adhesives and across pesticides, raw materials, samples, process and breeding plants, waste treatment plants, perm places
| Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
| Gas | Ethylene C2H4 |
| Measure Range | 0 to 1000 ppm |
| Resolution | 1ppm |
| Measurement principle | Non-dispersive infrared (NDIR) |
| Gas Detected | SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.) |
| Detection Uncertainty | <1.5 % F.S |
| Detection Resolution | 0.1ppm |
| Gas Detected | Nitrogen N2 |
| Detection principle | Electrochemical principles |
| Measurement Range | 0 to 100 %.Vol |
| Resolution | 0.01 %VOL |
| Sampling Method | Diffusion | ||||||
| Working conditions |
|
||||||
| Explosion proof grade | Exia II CT3 | ||||||
| Protection grade | IP65 |
| Sampling method | Diffusion | ||||
| Measurement principle | Electrochemical (oxygen, toxic gases), Catalytic combustion (flammable gases), Infrared principle (carbon dioxide gas) | ||||
| Detector gas | Flammable gases, oxygen gas, toxic and harmful gases | ||||
| Response time |
|
| Gas detected | Sulfur dioxide SO2 |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Measure range | 0 to1000 ppm |
| Gas detected | NO2 |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Measure range | 0 to1000 ppm |
| Sampling method | Diffusion |
| Sensor type | CO2: solid electrolyte sensor, O2:electrochemical sensor |
| Detection range | CO2:0.04 to 5.00 % and O2:0.0 to 30.0 % |
| Detection accuracy | CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale) |
| Measuring range | 0 ∼ 125 Pa |
| Accuracy | 0 ± 0.2 Pa (liner error) ± 1 % |
| Operating temperature range | 0 °C ∼ 50 °C |
| Operational humidity | ˂ 85 RH |
| Measuring range | ± 500 Pa |
| Repeatability | ± 0.2 % FS |
| Resolution | 0.1 Pa |
| Sampling rate | 0.5 s |
| Measurement range | 0 ppm ∼ 5 ppm |
| Resolution | 0.001 ppm ( 0 ppm ∼ 5 ppm ) |
| Temperature range | ˗ 40 °C ∼ 120 °C |
| Humidity range | 0 % ∼ 100 % RH |
| Ozone measurement range | 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional ) |
| Flow rate | 1.5 L/min |
| Accuracy | 0.01 ppm or 3 % of reading |
| Resolution | 0.001 ppm |
| Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
| Flow rate | 1 L/min |
| Accuracy | 0.01 ppm |
| Measuring time | 10 seconds |
| Temperature Measurement Range | -10℃ to 60℃ |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ± 1.5℃ |
| Relative Humidity Range | 20% to 80% RH |