Ask An Expert
Portable Single Gas Detector LPSG-A10 is a compact, lightweight detector. Detects the concentration of flammable gases, oxygen gas, and different types of toxic and harmful gases. It features large capacity lithium battery with long standby time, adjustable calibration concentration, and manual cancellation mode of vibration alarms.
Used in petroleum, chemical, fuel processing industry, metal manufacturing plants, drug production plants.
| Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
| Gas | Ethylene C2H4 |
| Measure Range | 0 to 1000 ppm |
| Resolution | 1ppm |
| Measurement principle | Non-dispersive infrared (NDIR) |
| Gas Detected | SF6: 0 to 50 ppm range/ 0 to 1000 ppm range (as per req.) |
| Detection Uncertainty | <1.5 % F.S |
| Detection Resolution | 0.1ppm |
| Gas Detected | O2 CH4 CO2 VOC CO H2S SO2 CL2 NO2 NH3 |
| Detection principle | Electrochemical principle (O2 CO H2S SO2 CL2 NO2 NH3) Infrared principle (CH4 CO) Photoionization principles (VOC) |
| Measurement Range | O2: 0-30% VOL, CH4: 0-50000 PPM, CO2:0-50000 PPM VOC:0-2000 PPM, CO:0-999 PPM, H2S: 0-200 PPM SO2: 0-25 PPM, CL2: 0-50 PPM, NO2: 0-100 PPM, NH3:0-100 PPM |
| Resolution | O2: 0.01% VOL, CH4: 1 PPM, CO2:1 PPM VOC:1 PPM, CO:0.1 PPM, H2S: 0.1 PPM SO2: 0.01 PPM, CL2: 0.01 PPM, NO2: 0.01 PPM, NH3:0.01 PPM |
| Gas Detected | Nitrogen N2 |
| Detection principle | Electrochemical principles |
| Measurement Range | 0 to 100 %.Vol |
| Resolution | 0.01 %VOL |
| Sampling Method | Diffusion | ||||||
| Working conditions |
|
||||||
| Explosion proof grade | Exia II CT3 | ||||||
| Protection grade | IP65 |
| Gas detected | Sulfur dioxide SO2 |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Measure range | 0 to1000 ppm |
| Gas detected | NO2 |
| Detection principle | Electrochemistry |
| Sampling method | Pumping suction, flow rate can up to 1L/min, ten grades of pumping suction for selection. |
| Measure range | 0 to1000 ppm |
| Sampling method | Diffusion |
| Sensor type | CO2: solid electrolyte sensor, O2:electrochemical sensor |
| Detection range | CO2:0.04 to 5.00 % and O2:0.0 to 30.0 % |
| Detection accuracy | CO2:± 30 % rdg (rdg = reading) and O2:± 3 % F.S. (F.S. = full scale) |
| Measuring range | 0 ∼ 125 Pa |
| Accuracy | 0 ± 0.2 Pa (liner error) ± 1 % |
| Operating temperature range | 0 °C ∼ 50 °C |
| Operational humidity | ˂ 85 RH |
| Measuring range | ± 500 Pa |
| Repeatability | ± 0.2 % FS |
| Resolution | 0.1 Pa |
| Sampling rate | 0.5 s |
| Measurement range | 0 ppm ∼ 5 ppm |
| Resolution | 0.001 ppm ( 0 ppm ∼ 5 ppm ) |
| Temperature range | ˗ 40 °C ∼ 120 °C |
| Humidity range | 0 % ∼ 100 % RH |
| Ozone measurement range | 0 ppm ∼ 5 ppm, 0 ppm ∼ 100 ppm, 0 ppm ∼ 300 ppm, 0 ppm ∼ 600 ppm ( Optional ) |
| Flow rate | 1.5 L/min |
| Accuracy | 0.01 ppm or 3 % of reading |
| Resolution | 0.001 ppm |
| Ozone measurement range | 0 ppm ∼ 100 ppm/ 0 ppm ∼ 1000 ppm |
| Flow rate | 1 L/min |
| Accuracy | 0.01 ppm |
| Measuring time | 10 seconds |
| Temperature Measurement Range | -10℃ to 60℃ |
| Temperature Resolution | 0.1°C |
| Temperature Accuracy | ± 1.5℃ |
| Relative Humidity Range | 20% to 80% RH |