Low Temperature Tester
Distillate Fuel Cold Filter Plugging Point Filter LLTT-A12
Ambient temperature:
(-10)℃ ~ 35 ℃
Power supply:
AC 220 V ± 10 %, 50 Hz
Pumping pressure:
U type differential pressure meter 1961 Pa (200 mm H2O)
Relative humidity:
≤ 85 %
Solidifying Point Tester LLTT-A13
Ambient temperature:
≤ 30 ℃
Cold trough:
Two holes in one trough, and same temperature
Dimensions:
620 x 460 x 355 mm
Power supply:
AC 220 V ± 10 %, 50 Hz
Solidifying Point and Cold Filter Plugging Point Tester LLTT-A15
Ambient temperature:
≤ 30 ℃
Controlling temperature of cold trough:
Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Inner Dimensions:
560 x 380 x 250 mm
Outer Dimensions:
920 x 670 x 510 mm
Multifunctional Low Temperature Tester LLTT-A16
Ambient temperature:
≤ 30 ℃
Controlling temperature of cold trough:
Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Dimensions:
930 x 570 x 108 mm
Power supply:
AC 220 V ± 10 %, 50 Hz;
Solidifying Point Tester LLTT-A20
Ambient temperature:
≤ 30 ℃
Cold trough:
One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough:
Room temperature ~ (-70) °C
Dimensions:
730 x 580 x 520 mm
Solidifying Point Tester (Solidifying Point and Cold Filter Plugging Point) LLTT-A21
Ambient temperature:
≤ 30 ℃
Cold trough:
One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough:
Room temperature ~ (-70) °C
Inner Dimensions:
560 x 380 x 250 mm
Solidifying Point Tester ('-20°C +80°C') LLTT-A22
Ambient temperature:
≤ 30 ℃
Cold trough:
One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough:
Room temperature ~ (-70) °C
Dimensions:
730 x 580 x 520 mm
Automatic Pour Point Tester LLTT-A23
Ambient temperature:
≤ 30 ℃
Dimensions:
610 x 450 x 580 mm
Power supply:
AC 220 V ± 10 %, 50 Hz
Pressure of cooling water:
0.5 kg / cm2
Solidifying Point Constant Temperature Water Bath LLTT-A10
Capacity:
20 L
Dimension (W×D×H):
530×400×670 mm
Heating:
Two grades
Heating power:
1000 W + 650 W
Freezing Point Tester LLTT-A11
Ambient temperature:
≤ 30°C
Bath liquids stirring:
Electric
Bath liquids stirring range:
1200 r/min
Cold bath measurement temperature range:
-70° to 20°C
Pour and Cloud Point Tester LLTT-A14
Ambient temperature:
≤ 30°C
Chamber 01 temperature control:
Ambient to -51 ℃
Chamber 02 temperature control:
Ambient to -65 ℃
Chamber quantity:
2 chambers