Ask An Expert
Meat Moisture Analyzer LMMA-A10 works on the principle that moisture, fat absorbs a specific wavelength of light. It offers sample capacity 0.001 to 120.000 g and works on molecular source heating method. The heating temperature range is from Room temperature to 220.0℃ and offers color 7 inch LCD touch screen display. Designed to give production and quality management personnel rapid access to reliable, repeatable and accurate data from meat samples collected from the process. It is used for moisture analysis, as well as the chemical methods used for measuring parameters such as fat or protein.
Meat Moisture Analyzer used in factory calibrated, ready for measurement in any meat processing factory for moisture, fat, protein, collagen, collagen/protein ratio. Also used for testing the moisture content of meat has become an important item in business management and food safety testing.
| Measurement Object | Poultry meat (pork, beef, lamb, chicken, etc.) |
| Moisture Measurement Range | 10% to 90% |
| Sampling Time | < 2s |
| Measurement Error In The Range | 70 to 78% ≤ 1.0% |
| Range | 10 mg to 110 g |
| Readability | 10 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-1 |
| Range | 5 mg to 110 g |
| Readability | 5 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-1 |
| Range | 2 mg to 110 g |
| Readability | 2 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-1 |
| Range | 1 mg to 110 g |
| Readability | 1 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-1 |
| Range | 1 mg to 110 g |
| Readability | 1 mg |
| Temperature range | 40 to 199°C |
| Heat source | Halogen lamp-2 |
| Range | 4 mg to 110 g |
| Readability | 1 mg |
| Temperature range | 40 to 230 °C |
| Communication mode | Cable |
| Range | 4 mg to 110 g |
| Readability | 1 mg |
| Temperature range | 40 to 230 °C |
| Communication mode | Wireless |
| Range | 4 mg to 210 g |
| Readability | 1 mg |
| Temperature range | 40 to 230 °C |
| Communication mode | Cable |
| Range | 4 mg to 210 g |
| Readability | 1 mg |
| Temperature range | 40 to 230 °C |
| Communication mode | Wireless |
| Measuring Element | Grain |
| Moisture Range | 3 % to 35 % |
| Repeating Error | ≤ 0.2 % |
| Measuring Error | ≤ ± 0.5 % |
| Measuring grains | 25 types |
| Measuring range | 3 to 80% |
| Operating temperature | 0 to 60°C |
| Operating humidity | 5 to 80% |
| Measuring Range | 0 to 99 % |
| Measurement Resolution | 0.0001 |
| Measuring Distance | 20 to 40 cm |
| Light Diameter | 10 cm |
| Measuring range | 0 % to 80 % |
| Resolution | 0.001 |
| Accuracy | 0 % to 10 % : ± 0.2 % 10 5 to 40 % : ± 0.5 % 40 % to 80 % : ± 1 % |
| Probe length | 600 mm |
| Measuring range | 0 to 40 % |
| Resolution | 0.001 |
| Accuracy | 0 to 10 %: ±0.2 % 10 to 40%: ±0.5 % |
| Scanning depth | 50 mm |