We offer a comprehensive collection of micropipettes with levels of accuracy and precision designed for better and quick one handed operation, these are used to dispense measured volume of liquids with a rapid release valve for quick and easy dispensing. These are autoclavable and light to use with disposable pipette tips.
| Test Volume | 5 μL |
| Accuracy error | 1.3 % |
| Precision error | 1.2 % |
| Test Volume | 10 μL |
| Accuracy error | 0.8 % |
| Precision error | 0.8 % |
| Test Volume | 20 μL |
| Accuracy error | 0.6 % |
| Precision error | 0.5 % |
| Test Volume | 25 μL |
| Accuracy error | 0.5 % |
| Precision error | 0.3 % |
| Test Volume | 50 μL |
| Accuracy error | 0.5 % |
| Precision error | 0.3 % |
| Test Volume | 100 μL |
| Accuracy error | 0.5 % |
| Precision error | 0.3 % |
| Test Volume | 200 μL |
| Accuracy error | 0.4 % |
| Precision error | 0.2 % |
| Test Volume | 250 μL |
| Accuracy error | 0.4 % |
| Precision error | 0.2 % |
| Test Volume | 500 μL |
| Accuracy error | 0.3 % |
| Precision error | 0.2 % |
| Test Volume | 1000 μL |
| Accuracy error | 0.3 % |
| Precision error | 0.2 % |
| Test Volume | 2000 μL |
| Accuracy error | 0.3 % |
| Precision error | 0.15 % |
| Test Volume | 5000 μL |
| Accuracy error | 0.3 % |
| Precision error | 0.15 % |
| Volume Range | 0.5 – 10 μL |
| Increment | 0.01 μL |
| Test Volume | 10 μL 1 μL |
| Accuracy Error | ±1.00 % ±3.50 % |
| Volume Range | 5 – 50 μL |
| Increment | 0.1 μL |
| Test Volume | 50 μL 5 μL |
| Accuracy Error | ±0.80 % ±3.00 % |
| Volume Range | 30 – 300 μL |
| Increment | 1 μL |
| Test Volume | 300 μL 30 μL |
| Accuracy Error | ±0.60 % ±3.00 % |
| Volume Range | 100 - 1000 μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 100 μL |
| Accuracy Error | ±0.60 % ±3.00 % |
| Volume Range | 0.1 - 2.5 μL |
| Increment | 0.05 μL |
| Test Volume | 2.5 μL 1.25 μL 0.25 μL |
| Accuracy error | 2.50 % 3.00 % 12.00 % |
| Volume Range | 0.5 - 10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| Accuracy error | 1.00 % 1.50 % 2.50 % |
| Volume Range | 2 - 20 μL |
| Increment | 0.5 μL |
| Test Volume | 20 μL 10 μL 2 μL |
| Accuracy error | 0.90 % 1.20 % 3.00 % |
| Volume Range | 5 - 50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| Accuracy error | 0.60 % 0.90 % 2.00 % |
| Volume Range | 10 - 100 μL |
| Increment | 1 μL |
| Test Volume | 100 μL 50 μL 10 μL |
| Accuracy error | 0.80 % 1.00 % 3.00 % |
| Volume Range | 20 - 200 μL |
| Increment | 1 μL |
| Test Volume | 200 μL 100 μL 20 μL |
| Accuracy error | 0.60 % 0.80 % 3.00 % |
| Volume Range | 50 - 200μL |
| Increment | 1 μL |
| Test Volume | 200 μL 100 μL 50 μL |
| Accuracy error | 0.60 % 0.80 % 1.00 % |
| Volume Range | 100 - 1000μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 500 μL 100 μL |
| Accuracy error | 0.60 % 0.70 % 2.00 % |
| Volume Range | 200 - 1000μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 500 μL 200 μL |
| Accuracy error | 0.60 % 0.70 % 0.90 % |
| Volume Range | 1000 - 5000 μL |
| Increment | 50 μL |
| Test Volume | 5000 μL 2500 μL 1000 μL |
| Accuracy error | 0.50 % 0.60 % 0.70 % |
| No of Channels | 8 |
| Volume Range | 0.5 -10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| No of Channels | 8 |
| Volume Range | 5-50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| No of Channels | 8 |
| Volume Range | 50-300 μL |
| Increment | 5 μL |
| Test Volume | 300 μL 150 μL 50 μL |
| No of Channels | 12 |
| Volume Range | 0.5-10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| No of Channels | 12 |
| Volume Range | 5-50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| No of Channels | 12 |
| Volume Range | 50-300 μL |
| Increment | 5 μL |
| Test Volume | 300 μL 150 μL 50 μL |
| No of Channels | 8 |
| Volume Range | 0.5 -10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| No of Channels | 8 |
| Volume Range | 5-50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| No of Channels | 8 |
| Volume Range | 50-300 μL |
| Increment | 5 μL |
| Test Volume | 300 μL 150 μL 50 μL |
| No of Channels | 12 |
| Volume Range | 0.5-10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| No of Channels | 12 |
| Volume Range | 5-50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| No of Channels | 12 |
| Volume Range | 50-300 μL |
| Increment | 5 μL |
| Test Volume | 300 μL 150 μL 50 μL |
| Volume Range | 0.1 - 2.5 μL |
| Increment | 0.05 μL |
| Test Volume | 2.5 μL 1.25 μL 0.25 μL |
| Accuracy error | 2.50 % 3.00 % 12.00 % |
| Volume Range | 0.5 - 10 μL |
| Increment | 0.1 μL |
| Test Volume | 10 μL 5 μL 1 μL |
| Accuracy error | 1.00 % 1.50 % 2.50 % |
| Volume Range | 2 - 20 μL |
| Increment | 0.5 μL |
| Test Volume | 20 μL 10 μL 2 μL |
| Accuracy error | 0.90 % 1.20 % 3.00 % |
| Volume Range | 5 - 50 μL |
| Increment | 0.5 μL |
| Test Volume | 50 μL 25 μL 5 μL |
| Accuracy error | 0.60 % 0.90 % 2.00 % |
| Volume Range | 10 - 100 μL |
| Increment | 1 μL |
| Test Volume | 100 μL 50 μL 10 μL |
| Accuracy error | 0.80 % 1.00 % 3.00 % |
| Volume Range | 20 - 200 μL |
| Increment | 1 μL |
| Test Volume | 200 μL 100 μL 20 μL |
| Accuracy error | 0.60 % 0.80 % 3.00 % |
| Volume Range | 50 - 200μL |
| Increment | 1 μL |
| Test Volume | 200 μL 100 μL 50 μL |
| Accuracy error | 0.60 % 0.80 % 1.00 % |
| Volume Range | 100 - 1000μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 500 μL 100 μL |
| Accuracy error | 0.60 % 0.70 % 2.00 % |
| Volume Range | 200 - 1000μL |
| Increment | 5 μL |
| Test Volume | 1000 μL 500 μL 200 μL |
| Accuracy error | 0.60 % 0.70 % 0.90 % |
| Volume Range | 1000 - 5000 μL |
| Increment | 50 μL |
| Test Volume | 5000 μL 2500 μL 1000 μL |
| Accuracy error | 0.50 % 0.60 % 0.70 % |
| Volume Range | 2 - 10 mL |
| Increment | 0.1 mL |
| Test Volume | 10 mL 5 mL 2 mL |
| Accuracy error | 0.60 % 1.20 % 3.00 % |
Pipet Controller is a light, ergonomic pipette controller designed for use with glass and plastic serological pipets from 0.1 to 100 mL. Suitably placed switches change operating modes and speeds quickly to handle different liquid volumes. When fully charged, the batteries enable up to 8 hours of constant use. The large LCD display clearly indicated battery status and speed.
| Aspiration speed | 25 ml < 7s |
| Dispensing speed | Motor/gravity |
| Aspiration/Dispensing speed | NA |
| Pipette type | Plastic and glass pipettes, Pasteur pipette |
| Aspiration speed | 25 ml < 5s |
| Dispensing speed | Motor/gravity |
| Aspiration/Dispensing speed | 8 shifts |
| Pipette type | Plastic and glass pipettes, Pasteur pipette |