Portable Airborne Particle Counter LPPC-A30 is a six channel microcomputer controlled unit. It has a provision of simultaneously counting particles in six different size ranges with real time monitoring. Equipped with built-in thermal sensitive printer for direct printing of pre-recorded and current data for end user convenience. Designed with large LCD screen for displaying particle count of all channels. The particle count data can be conveniently viewed, downloaded or printed directly using the built-in printer featuring multiple print mode.
Portable Airborne Particle Counter is used in clean room monitoring, indoor air quality testing, filter testing, tracking particle sources, pharmaceuticals, R&D labs, and electronics, semiconductor industries; monitoring of biosafety cabinets, clean benches, computer rooms and HVAC system performance; in fields of optics, aerospace, pharmaceutical, electronics, food hygiene industry, etc.
| Particle size channels | 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm |
| Flow Rate | 0.1 CFM ( 2.83 L/min ) |
| Test class | Class 100 ∼ Class 300,000 |
| Built-in battery | No |
| Particle size channels | 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm |
| Flow Rate | 0.1 CFM ( 2.83 L/min ) |
| Test class | Class 100 ∼ Class 300,000 |
| Built-in battery | Yes |
| Particle size channels | 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm |
| Flow Rate | 1 CFM ( 28.3 L/min ) |
| Test class | Class 100 ∼ Class 300,000 |
| Test period | 1 min ∼ 10 min |
| Particle size channels | 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm |
| Flow Rate | 0.1 CFM ( 2.83 L/min ) |
| Test class | Class 100 ∼ Class 300,000 |
| Test period | 1 min ∼ 10 min |
| Particle size channels | 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm |
| Flow Rate | 1.0 CFM ( 28.3 L/min ) |
| Sensitivity | 0.3 µm |
| Test period | 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L ) |
| Particle size channels | 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm |
| Flow Rate | 50 L/min |
| Sensitivity | 0.3 µm |
| Test period | 1 sec ∼ 3599 sec ( 5 L ∼ 3000 L ) |
| Particle size channels | 0.3 µm, 0.5 µm, 0.7 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm, 10.0 µm |
| Flow Rate | 100 L/min |
| Sensitivity | 0.3 µm |
| Test period | 1 sec ∼ 5999 sec ( 5 L ∼ 3000 L ) |
| Particle size channels | 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm |
| Flow rate | 0.1 CFM ( 2.83 L/min ) |
| Test class | Class 100 ∼ Class 300,000 |
| Test period | 1 min ∼ 15 min ( 15 levels ) |
| Particle size channels | 0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm |
| Flow rates | 2.83 L/min 50 mL/min |
| Sensitivity | 0.3 µm |
| Test class | Class 100 ∼ Class 300,000 |
| Particulate matter concentration | PM10, PM2.5, PM1.0, TSP |
| Particulate channels and size | 15 channels, 0.3 to 25 µm |
| Sensitivity | 0.0001 mg/m3 |
| Measuring Range | 0.01 to 20 mg/m3 |
| Measurement range | PM 1.0, PM 2.5, and PM 10.0 |
| Resolution | 0.1 µg/m3 |
| Concentration limits | 1000 µg/m3 |
| Accuracy | 0.1 |