Single Punch Tablet Press Machine LSTP-A11 comes with 50 KN Maximum pressure and offers 20 mm maximum diameter. Features a small desktop type press for motive and continual sheeting. It can also be hand-operated. Only one pair of punching die can be erected on this press. Both filling depth of material and thickness of tablet are adjustable. Designed with high precision of filling, low noise, low consumption, of material, and it works smoothly. The maximum consumption of lab material is just 200 g. Tablets of different granular materials are pressed under pressure for use in research and quality preparations across pharmaceutical, food, chemical industry, cosmetic industry etc.
Single Punch Tablet Press Machine is used in pharmaceutical, chemical, food, hospital, science research institution also used in manufacturing, production of small amount of different kinds of tablet, sugar piece, calcium tablet and tablet of abnormal shape.
| Maximum pressure | 60 KN |
| Maximum diameter Tablet | 25 mm |
| Maximum depth of filling | 16 mm |
| Maximum thickness of tablet | 10 mm |
| Maximum pressure | 15 KN |
| Maximum diameter Tablet | 12 mm |
| Maximum depth of filling | 11 mm |
| Maximum thickness of tablet | 6 mm |
| No of vessels | 1 |
| No of poles | 1 |
| Position of vessels and poles | One vessel and one pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 3 |
| No of poles | 3 |
| Position of vessels and poles | Three vessel and three pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Six vessel and six pole arranged on one line |
| Head part movement | Manually turn over |
| No of vessels | 6 |
| No of poles | 6 |
| Position of vessels and poles | Six vessel and six pole arranged on one line |
| Head part movement | Electrically turn over |
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in front and other two vessels at back |
| Head part movement | Manually turn over |
| No of vessels | 8 |
| No of poles | 6 |
| Position of vessels and poles | Six vessels and six poles in front and other two vessels at back |
| Head part movement | Electrically turn over |
| No of vessels | 8 |
| No of poles | 8 |
| Position of vessels and poles | Four vessels and four poles in front and others at back |
| Head part movement | Electrically turn over |
| No of vessels | 12 |
| No of poles | 12 |
| Position of vessels and poles | Six vessels and six poles in front and other six poles and vessels at back |
| Head part movement | Electrically (automatic) turn over |
| Number of basket lifting set | 1 set |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Minimum spacing from screen to bottom of beaker | 25 ± 2 mm |
| Number of basket lifting set | 2 sets |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Minimum spacing from screen to bottom of beaker | 25 ± 2 mm |
| Number of basket lifting set | 3 sets |
| Lifting frequency of the basket | 30 to 32/ min |
| Lifting distance of basket | 55 ± 1 mm |
| Minimum spacing from screen to bottom of beaker | 25 ± 2 mm |
| Hardness measurement range | 2 to 196 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 20 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | No |
| Hardness measurement range | 2 to 200 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 40 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | No |
| Hardness measurement range | 2 to 200 N, 0.2 to 20 kg |
| Tablet diameter | 2 to 40 mm |
| No. of testing tablets in each group | ≤ 100 tablets |
| Built in printer | Yes |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 25 rpm |
| Rotating accuracy | ± 1 rpm |
| Counting mode | Adopted with countdown, 100 turns can be set arbitrarily |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 20 to 100 rpm can be set arbitrarily |
| Rotating accuracy | ± 1 rpm |
| Counting mode | Adopted with countdown, 5 to 900 turns can be set arbitrarily |
| Number of cylinder | 2 |
| Rotating speed of cylinders | 25 rpm can be set arbitrarily |
| Rotating accuracy | ± 1 rpm |
| Counting mode | Adopted with countdown, 5 to 900 turns can be set arbitrarily |
| Number of cylinder | 1 |
| Rotating speed of cylinders | 25 rpm |
| Rotating accuracy | ± 1 rpm |
| Counting mode | 10 to 900 turns can be set arbitrarily |
| Diameter of counting plate | 400 mm |
| Hole No. of counting slide/range | 5 to 100 (optional) |
| Production efficiency | 10 to 20 vials/ min |
| Rate of Bottles | 36 bottles/ minute |
| Material Stainless | 316 L Stainless Steel |
| Automatic Grade | Semi-Automatic |
| Power Source | Pneumatic |
| Filling Head | Single Head or Double Head or Customized |
| Disc | Diameter 100 mm |
| Funnel Outer Diameter | Outer diameter 155 mm |
| Funnel Inner Diameter | 145 mm |
| Test Sample | Surfactant Powder and Particles, non-agglomerated powder |
| Work Station | 1 |
| Sample Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |
| Work Station | 2 |
| Sample Volume | ≤ 250 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |
| Work Station | 3 |
| Sample Volume | ≤ 100 ml |
| Sample Weight | ≤ 500 g |
| Number of Tapping | 0 to 99999 (set 0 to output bulk density) |