Portable turbidity meter LTM-A16
Light source: LED/860 nm (Wavelength)
Readings display: LCD
Unit switches: NTU, FTU, EBC, ASBC
Measurement range: 0.00-20.0; 20.01-200; 200.01-1000 NTU
Portable Turbidity Meter LTM-A10
Measuring range (NTU): 0 to 200
Minimum readout value (NTU): 0.1
Calibration point: Nil
Sample volume: 5 to 10 ml
Portable Turbidity Meter LTM-A11
Measuring range (NTU): 0 to 100, 0 to 200
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 4
Sample volume: 5 to 10 ml
Portable Turbidity Meter LTM-A12
Measuring range (NTU): 0 to 100, 100 to 400
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 5
Sample volume: 5 to 10 ml
Portable Turbidity Meter LTM-A13
Measuring range (NTU): 0 to 100, 100 to 500
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 6
Sample volume: 5 to 10 ml
Portable Turbidity Meter LTM-A14
Measuring range (NTU): 0 to 100, 100 to 800
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 6
Sample volume: 5 to 10 ml
Portable Turbidity Meter LTM-A15
Measuring range (NTU): 0 to 100, 100 to 1000
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 7
Sample volume: 5 to 10 ml
Bench top Turbidity Meter LTM-B10
Measuring range (NTU): 0 to 100
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 1
Sample volume: 5 to 10 ml
Bench top Turbidity Meter LTM-B11
Measuring range (NTU): 0 to 50, 0 to 100, 0 to 200
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 3
Sample volume: 5 to 10 ml
Bench top Turbidity Meter LTM-B12
Measuring range (NTU): 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 4
Sample volume: 5 to 10 ml
Bench top Turbidity Meter LTM-B13
Measuring range (NTU): 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 5
Sample volume: 5 to 10 ml
Bench top Turbidity Meter LTM-B14
Measuring range (NTU): 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000
Minimum readout value (NTU): 0.01, 0.1
Calibration point: 6
Sample volume: 5 to 10 ml
Bench top Turbidity Meter (with built-in printer) LTM-C10
Measuring range (NTU): 0 to 100, 0 to 200
Minimum readout value (NTU): 0.01
Calibration point: 2
Sample volume: 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C11
Measuring range (NTU): 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU): 0.01
Calibration point: 3
Sample volume: 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C12
Measuring range (NTU): 0 to 10, 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU): 0.001
Calibration point: 4
Sample volume: 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C13
Measuring range (NTU): 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU): 0.01
Calibration point: 5
Sample volume: 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C14
Measuring range (NTU): 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU): 0.001
Calibration point: 5
Sample volume: 18 to 20 ml
Bench top Turbidity Meter (with built-in printer) LTM-C15
Measuring range (NTU): 0 to 10, 0 to 100
Minimum readout value (NTU): 0.001
Calibration point: 2
Sample volume: 18 to 20 ml