Detector Specifications: | {"Model No":"HPD-B2","Wavelength range":"190 to 800 nm","Wavelength accuracy":"\u00b1 0.75 nm","Wavelength repeatability":"0.2 nm","Band width":"8 nm","Optical path":"10 nm","Deuterium lamp":"190 to 400 nm","Tungsten lamp":"400 to 800 nm","Baseline noise ( Static ) Au":"\u2264 \u00b1 0.5 \u00d7 10 -5<\/sup>","Baseline drift ( Static ) Au \/ h":"\u2264 1.5 x 10 -4<\/sup>","Minimum detection limit":"\u2264 4 x 10 -8<\/sup>","Power":"100 W","Power supply":"90 V \/ 50 to 60 Hz","Dimension":"460 \u00d7 260 \u00d7 190 mm","Weight":"9.2 kg"} |
Pump Specifications: | {"Model No":"HPP-B1","Flow rate range":"0.0001 to 10 ml \/ min","Maximum pressure":"42 MPa , 0 to 5 ml \/ min","Column size":"4.6 \u00d7 250 mm","Sample size":"5 \u03bcm","Pressure pulsation":"\u2264 1.5 % at 10 MPa","Flow rate accuracy":"\u00b1 0.2 % at 1 ml \/ min","Flow rate repeatability %":"\u2264 0.15","Gradient accuracy %":"\u00b1 2","Gradient repeatability %":"\u2264 0.2","Dimension":"450 \u00d7 260 \u00d7 190 mm","Power supply":"90 V to 240 V","Weight":"11.2 kg"} |
Detector Specifications: |
|
|||||||||||||||||||||||||||||||||||||||||||||
Pump Specifications: | {"Flow rate range":"0.0001 to 10 ml \/ min","Maximum pressure":"50 MPa , 0 to 2 ml \/ min","Column size":"4.6 \u00d7 250 mm","Sample size":"5 \u00b5m","Pressure pulsation":"\u2264 1 % at 10 MPa","Flow rate accuracy":"\u00b1 0.15 % at 1 ml \/ min","Flow rate repeatability %":"\u2264 0.1","Gradient accuracy %":"\u00b1 1.5","Gradient repeatability %":"\u2264 0.2","Dimension":"460 \u00d7 310 \u00d7 180 mm","Power supply":"90 V","Weight":"11.6 kg"} |
Detector Specifications: | {"Wavelength range":"190 to 700 nm","Wavelength accuracy":"\u00b1 1 nm","Wavelength repeatability":"0.2 nm","Deuterium lamp":"190 to 400 nm","Tungsten lamp":"400 to 700 nm","Baseline noise ( Static ) Au":"1 \u00d7 10-5<\/sup> AU\/h at 254 nm with methanol\/water= 80\/20","Baseline drift ( Static ) Au \/ h":"1.5 \u00d7 10-4<\/sup> AU\/h at 254 nm with methanol\/ water= 80\/20","Time constants":"16 grades adjustable","Display":"LCD backlight display","GLP":"Total number of lights, lamp replacement time and product serial number","Power":"75 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension (L \u00d7 W \u00d7 H)":"398 \u00d7 149 \u00d7 267 mm"} |
Pump Specifications: | {"Solvent delivery":"Double plunger series mode, floating plunger design, single stroke volume 30 \u00b5l","Pump Head":"10 ml stainless steel pump head","Flow rate range":"0.001 to 9.999 ml \/ min","Flow rate increment":"0.001 ml\/min","Maximum pressure":"42 MPa","Column size":"4.6 \u00d7 250 mm 5 \u00b5m","Pipeline Size":"1\/16 inch","Flow rate accuracy":"\u00b1 0.5 %","Flow rate precision":"RSD \u2264 0.1%","Gradient accuracy %":"\u00b1 0.5 %","Gradient repeatability %":"RSD \u2264 0.15%","GLP":"Automatic recording of pump sealing ring working time","Display":"LCD backlight display","Power":"80 W","Power supply":"220 V \u00b1 10%, 50 Hz","Dimension":"398 \u00d7 149 \u00d7 267 mm"} |
Data-processing Workstation: | System contain the tables for regular samples Equipped with Internal and external standard calculation process Automatic display, print, export of data and starting of another program on completion on measurement Observe with the condition of 21 CFR part 11 directive of the FDA |
Dimension: | 710 × 583× 500mm; 770 × 450 × 700 mm |
Power Supply: | AC 110 /220 V ±1 0 %, 50/60 Hz |
Pump specification: | {"Type":"Quaternary Low Pressure Pump","Flow Rate Range":"0.001 to 10.000 ml\/min, in 0.001ml increments","Flow Accuracy":"\u2264 \u00b1 0.2% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5 MPa)","Flow Precision":"RSD \u2264 0.06% (1.00 ml\/min, H2 <\/sub>O, R.T., 8.5MPa)","Maximum Pressure":"63 MPa","Pressure accuracy":"\u2264 \u00b1 3.0 %","Pressure pulsation":"\u2264 0.1 MPa","Composition rang":"0 to 100 %","Composition precision":"\u2264 0.3 % RSD"} |
High Pressure Constant Flow Pump: | {"Double plunger reciprocating pump":"1 set","Flow range":"0.001 to 10.00 mL\/min","Setting step size":"0.001 mL\/min","Flow accuracy":"\u2264 \u00b1 0.3 %","Flow stability":"RSD \u2264 00.1 %","Maximum pressure":"42 MPa","Display pressure error":"\u2264 1.0 %","Pressure fluctuation":"\u2264 1.0 %","Power consumption":"80 W"} |
UV/Visible Detector: | {"Wavelength range":"190 to 700 nm","Wavelength repeatability":"\u00b1 0.1 nm","Band width":"8 nm","Response time":"0 to 4.9 seconds","Linearity range":"1.8 AU (5 %)","Baseline Noise":"\u2264 \u00b1 1 \u00d7 10-5<\/sup>AU","Baseline drift":"\u2264 2.0 \u00d7 10-4<\/sup>AU\/h","Minimum detectable concentration":"4.0 \u00d7 10-9<\/sup> g\/mL","Detector cell":"Optical path: 10 mm \nVolume: 10 \u00b5L","Light source":"Deuterium lamp","Power consumption":"100 W","Voltage":"AC 110 V\/ 220 V \u00b1 10 %, 50\/60 Hz","Packing Dimensions (W \u00d7 D \u00d7 H)":"600 \u00d7 440 \u00d7 380 mm \n2 \u00d7 (600 \u00d7 410 \u00d7 300 mm","Gross weight":"54 kg"} |
High Pressure Constant Flow Pump: | {"Double plunger reciprocating pump":"2 sets","Flow range":"0.001 to 10.00 mL\/min","Setting step size":"0.001 mL\/min","Flow accuracy":"\u2264 \u00b1 0.3 %","Flow stability":"RSD \u2264 00.1 %","Maximum pressure":"42 MPa","Display pressure error":"\u2264 1.0 %","Pressure fluctuation":"\u2264 1.0 %","Power consumption":"80 W"} |
UV/Visible Detector: | {"Wavelength range":"190 to 700 nm","Wavelength repeatability":"\u00b1 0.1 nm","Band width":"8 nm","Response time":"0 to 4.9 seconds","Linearity range":"1.8 AU (5 %)","Baseline Noise":"\u2264 \u00b1 1 \u00d7 10-5<\/sup>AU","Baseline drift":"\u2264 2.0 \u00d7 10-4<\/sup>AU\/h","Minimum detectable concentration":"4.0 \u00d7 10-9<\/sup> g\/mL","Detector cell":"Optical path: 10 mm \nVolume: 10 \u00b5L","Light source":"Deuterium lamp","Power consumption":"100 W","Voltage":"AC 110 V\/ 220 V \u00b1 10 %, 50\/60 Hz","Packing Dimensions (W \u00d7 D \u00d7 H)":"600 \u00d7 440 \u00d7 380 mm \n3 \u00d7 (600 \u00d7 410 \u00d7 300 mm","Gross weight":"75 kg"} |