Ask An Expert

Viscometer LVM-D10
Measurement range: 25 mPa.s to 1×10000000 mPa.s
Rotors: Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed: (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range: 45 to 200°C
Viscometer LVM-D11
Measurement range: 100 mPa.s to 200000 mPa.s
Rotors: Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed: 5, 10, 20, 50 r/min
Temperature control range: Room temperature to 200°C
Viscometer LVM-D12
Measurement range: 100 mPa.s to 2000000 mPa.s
Rotors: Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed: 5, 10, 20, 50 r/min
Temperature control range: 45 to 200°C
Viscometer LVM-A20
Viscosity Range: LV: 1 to 2000000 mPa.s
Rotation speed range: 0.3 to 100 rpm (stepless)
Spindles: LV: (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy: ± 1.0 % (of full range)
Viscometer LVM-A21
Viscosity Range: RV: 100 to 13000000 mPa.s
Rotation speed range: 0.3 to 100 rpm (stepless)
Spindles: RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy: ± 1.0 % (of full range)
Viscometer LVM-A22
Viscosity Range: HA: 200 to 26000000 mPa.s
Rotation speed range: 0.3 to 100 rpm (stepless)
Spindles: HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy: ± 1.0 % (of full range)
Viscometer LVM-A23
Viscosity Range: HB: 800 to 104000000 mPa.s
Rotation speed range: 0.3 to 100 rpm (stepless)
Spindles: HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy: ± 1.0 % (of full range)
Viscometer LVM-A30
Viscosity Range: LV: 1 to 6000000 mPa.s
Rotation speed range: 0.1 to 250 rpm
Spindles: (1#, 2#, 3#, 4# spindles) (0# is optional)
Accuracy: ± 1.0% (of full range)
Viscometer LVM-A31
Viscosity Range: RV: 100 to 40000000 mPa.s
Rotation speed range: 0.1 to 250 rpm
Spindles: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional)
Accuracy: ± 1.0% (of full range)
Viscometer LVM-B10
Measuring range: 0.1 to 100,000 mPa.s
Rotating speed: 6/12/30/60 (r/min)
Rotor: 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid): ±1%
Viscometer LVM-B11
Measuring range: 0.1 to 2,000,000 mPa.s
Rotating speed: 0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor: 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid): ±1%
Viscometer LVM-C10
Measuring range: 1 to 100000 mPa.s
Rotating speed: 3/6/12/30/60 (r/min)
Rotor: 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid): ±1%
Viscometer LVM-C11
Measuring range: 1 to 100000 mPa.s
Rotating speed: 3/6/12/30/60 (r/min)
Rotor: 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid): ±0.5%
Viscometer LVM-C12
Measuring range: 1 to 200000 mPa.s
Rotating speed: 0.3/0.6/1.5/3.6/12/30/60 (r/min)
Rotor: 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid): ±1%
Viscometer LVM-C13
Measuring range: 1 to 600000 mPa.s
Rotating speed: 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor: 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid): ±1%
Viscometer LVM-A10
Measuring range: 1 - 6,000,000 cP, 100 - 40,000,000 cP, 200 - 80,000,000 cP, 800 - 320,000,000 cP
Rotating speed: 0.1 - 200 rpm
Measuring Error (Newtonian liquid): ± 1.0 % full range
Repeatability error (Newtonian liquid)): ± 0.5 %
Viscometer LVM-A41
Rotational speed range: 0.3 to 100 rpm
Standard Rotor: Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
Viscosity measurement range: Rotor R2 to R7:100 to 4000 M (mPa.s)
Standard Rotor Sample Dosage: Rotor R1 to R7: 500 ml
Viscometer LVM-A40
Viscosity Range: 3 to 1600000 M (mPa.s)
Rotation speed range: 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm
Spindles: 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml
Rotor: 18#,25#,31#,34# (standard configuration)
Viscometer LVM-D20
Viscosity Range: 40.2 KU to 141.0 KU
32 g to 1099 g
27 to 5250 CP
Rotation speed range: 200±0.1 rpm
Accuracy: ± 3 %
Repeatability: ±1.5 %
Viscometer LVM-A42
Rotational speed range: 0.3 to 100 rpm
Standard Rotor: Rotor R2 to R7 (6, Standard), R1 (Apolegamy)
Viscosity measurement range: Rotor R2 to R7:200 to 26 M (mPa.s)
Standard Rotor Sample Dosage: Rotor R1 to R7: 500 ml

 Enquiry Now