Labtron Viscometer LVM-A10 is especially designed with spindles for measuring shear rate and shear stress. In addition to providing accurate shear rate and shear stress, they are configured with Resistance Temperature Detector (RTD) and stepper motor for accurate and reliable operation.
Our product Viscometer has its use in quality control applications to give precise and accurate results of viscosity measurement, also it is used to study flow behavior of liquid and semi solid materials like pharmaceuticals, juices, dairy products, organic solvent, ink, glue, polymer solutions, cosmetics, etc.
| Viscosity Range | LV: 1 to 2000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | LV: (1#, 2#, 3#, 4# spindles) (0# is optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | RV: 100 to 13000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | RV: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | HA: 200 to 26000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | HA: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | HB: 800 to 104000000 mPa.s |
| Rotation speed range | 0.3 to 100 rpm (stepless) |
| Spindles | HB: (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0 % (of full range) |
| Viscosity Range | LV: 1 to 6000000 mPa.s |
| Rotation speed range | 0.1 to 250 rpm |
| Spindles | (1#, 2#, 3#, 4# spindles) (0# is optional) |
| Accuracy | ± 1.0% (of full range) |
| Viscosity Range | RV: 100 to 40000000 mPa.s |
| Rotation speed range | 0.1 to 250 rpm |
| Spindles | (2#, 3#, 4#, 5#, 6#, 7#, 6 Spindles) (0#, 1# are optional) |
| Accuracy | ± 1.0% (of full range) |
| Viscosity Range | 3 to 1600000 M (mPa.s) |
| Rotation speed range | 0.3/0.6/1.5/3/6/10/12/15/20/25/30/40/50/60/70/80/90/100 Total 18 rpm |
| Spindles | 18# rotor:3 to 10 K; 7 ml 25# rotor:480 to 1.6 M; 9 ml 31# rotor:30 to 100 K; 10.5 ml 34# rotor:60 to 200 K; 11 ml |
| Rotor | 18#,25#,31#,34# (standard configuration) |
| Rotational speed range | 0.3 to 100 rpm |
| Standard Rotor | Rotor R2 to R7 (6, Standard), R1 (Apolegamy) |
| Viscosity measurement range | Rotor R2 to R7:100 to 4000 M (mPa.s) |
| Standard Rotor Sample Dosage | Rotor R1 to R7: 500 ml |
| Rotational speed range | 0.3 to 100 rpm |
| Standard Rotor | Rotor R2 to R7 (6, Standard), R1 (Apolegamy) |
| Viscosity measurement range | Rotor R2 to R7:200 to 26 M (mPa.s) |
| Standard Rotor Sample Dosage | Rotor R1 to R7: 500 ml |
| Measuring range | 0.1 to 100,000 mPa.s |
| Rotating speed | 6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 0.1 to 2,000,000 mPa.s |
| Rotating speed | 0.3/0.6/1.5/3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 100000 mPa.s |
| Rotating speed | 3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 100000 mPa.s |
| Rotating speed | 3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±0.5% |
| Measuring range | 1 to 200000 mPa.s |
| Rotating speed | 0.3/0.6/1.5/3.6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 1 to 600000 mPa.s |
| Rotating speed | 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min) |
| Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
| Measuring Error (Newtonian liquid) | ±1% |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 2 |
| Bath volume | 25 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 4 |
| Bath volume | 33 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.3 - 50000 mm2/s |
| Measure position | 6 |
| Bath volume | 41 L |
| Timing accuracy | 0.01 s |
| Measuring range | 0.35 to 5000 mm2/s |
| Measure position | 2 (4 units measuring position at option) |
| Bath volume | 12 L |
| Timing accuracy | 0.01 s |
| Measure position | 1 |
| Oil bath medium | Polydimethylsiloxane |
| Oil bath temperature range | 10 °C to 180 °C |
| Bath volume | 8 L |
| Accuracy | ± 2 % (F.S) | ||||||||||||||||||
| Temperature | -1℃ to 150℃ (± 0.1℃) | ||||||||||||||||||
| Spindle Details |
|
||||||||||||||||||
| Note | rotate speed (rpm); Viscosity Range: (mPa.s), 1 poise = 100 mPa.s |