Ask An Expert
Labtron model of LUVC-A20 is equipped with UV carbon lamps to carry out UV testing along with temperature, humidity and rain to test the aging resistance to provide an accurate environment condition to give precise test results.
The UV Test Chamber is widely used in plastics, printing and packaging, paint, resins, adhesives, automotive, cosmetics, metals, electroplating, medicine, etc.
| UV Temperature | 50 °C to 75 °C |
| Testing Capacity | 48 piece (75 x 150 mm); 50 piece (75x 150 mm) |
| Weight | 136 kg |
| Water Consumption | Distilled water, 8liters per day |
| Temperature Range | RT + 100 °C ~ 630 °C |
| Humidity range | 30 % ~ 85 % RH |
| Testing Time | 20 hours |
| Testing Voltage | 120 V ~ 145 V |
Drug test chambers are designed to conduct stability and shelf life studies on drug and drugs components.
| Interior Volume | 100 L |
| Heat load | 1000 W |
| Temperature Range | 0℃ to 100 ℃ |
| Temperature Deviation in time | ± 2.0 ℃ |
| Interior Volume | 225 L |
| Heat load | 1000 W |
| Temperature Range | 0℃ to 100 ℃ |
| Temperature Deviation in time | ± 2.0 ℃ |
| Interior Volume | 500 L |
| Heat load | 1000 W |
| Temperature Range | 0℃ to 100 ℃ |
| Temperature Deviation in time | ± 2.0 ℃ |
| Interior Volume | 800 L |
| Heat load | 1000 W |
| Temperature Range | 0℃ to 100 ℃ |
| Temperature Deviation in time | ± 2.0 ℃ |
| Interior Volume | 1000 L |
| Heat load | 1000 W |
| Temperature Range | 0℃ to 100 ℃ |
| Temperature Deviation in time | ± 2.0 ℃ |
| Volume | 150 L |
| Temperature Range | 0 - 65 °C |
| Temperature Fluctuation | ± 0.5 °C |
| Temperature Control Precision | 0.1 °C |
| Volume | 250 L |
| Temperature Range | 0 - 65 °C |
| Temperature Fluctuation | ± 0.5 °C |
| Temperature Control Precision | 0.1 °C |
| Volume | 500 L |
| Temperature Range | 0 - 65 °C |
| Temperature Fluctuation | ± 0.5 °C |
| Temperature Control Precision | 0.1 °C |
| Volume | 150 L |
| Temperature Range(without illumination) | 0 - 65 °C |
| Temperature Range(with illumination) | 10 °C - 65°C |
| Temperature Fluctuation | ± 0.5 °C |
| Volume | 250 L |
| Temperature Range(without illumination) | 0 - 65 °C |
| Temperature Range(with illumination) | 10 °C - 65°C |
| Temperature Fluctuation | ± 0.5 °C |
| Volume | 500 L |
| Temperature Range(without illumination) | 0 - 65 °C |
| Temperature Range(with illumination) | 10 °C - 65°C |
| Temperature Fluctuation | ± 0.5 °C |
Labtron offers ozone test chambers which can simulate ozone atmospheric conditions to be used for aging cracking test of non-metal materials and rubber products, to determine the anti-ozone properties of the products.
| Temperature range | 0℃ ~ 100℃ |
| Humidity range | 30 % - 98 % R.H |
| Temperature fluctuation | ± 0.5 ℃ |
| Speed rate for cooling | Ambient ~ 0 ℃ within 20 min |
| Diameter of holder (mm) | 400 |
| Length of each side (mm) | 180 |
| Temperature range | 0℃ ~ 100℃ |
| Humidity range | 30 % - 98 % R.H |
| Diameter of holder (mm) | 600 |
| Length of each side (mm) | 220 |
| Temperature range | 0℃ ~ 100℃ |
| Humidity range | 30 % - 98 % R.H |
| Diameter of holder (mm) | 700 |
| Length of each side (mm) | 350 |
| Temperature range | 0℃ ~ 100℃ |
| Humidity range | 30 % - 98 % R.H |
| Diameter of holder (mm) | 900 |
| Length of each side (mm) | 460 |
| Temperature range | 0℃ ~ 100℃ |
| Humidity range | 30 % - 98 % R.H |
Labtron’s plant growth chamber is designed with accurate control of temperature, light, humidity, CO2 and other environmental factors which are necessary for plant growth. These chambers are helpful for researchers to carryout different experiments on plants without any dependency on climatic factors.
| Chamber Volume | 300 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
| Chamber Volume | 450 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
| Chamber Volume | 800 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
| Chamber Volume | 1000 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
| Chamber Volume | 250 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
| Chamber Volume | 300 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
| Chamber Volume | 450 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
| Chamber Volume | 800 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
| Chamber Volume | 1000 L |
| Shelves | 3(PCS) |
| Display Resolution | 0.1 ℃ |
| Temperature Range | Without Lighting: 0 to 50℃ With lighting:10 to 50℃ |
Labtron offers wide range of salt spray corrosion test systems with ability to test the corrosive resistant of products. Our user friendly products suit our clients' requirement and hence, continue to be in demand.
| Testing room capacity | 110 L |
| Temperature range | Ambient to +60°C |
| Humidity range | 95 to 98% RH |
| Temperature Fluctuation | ± 0.5 ℃ |
| Testing room capacity | 326 L |
| Temperature range | Ambient to +60°C |
| Humidity range | 95 to 98% RH |
| Temperature Fluctuation | ± 0.5 ℃ |
| Testing room capacity | 410 L |
| Temperature range | Ambient to +60°C |
| Humidity range | 95 to 98% RH |
| Temperature Fluctuation | ± 0.5 ℃ |
| Testing room capacity | 780 L |
| Temperature range | Ambient to +60°C |
| Humidity range | 95% to 98% RH |
| Temperature Fluctuation | ± 0.5 ℃ |
| Testing room capacity | 1030 L |
| Temperature range | Ambient to +60°C |
| Humidity range | 95% to 98% RH |
| Temperature Fluctuation | ± 0.5 ℃ |
| Testing room capacity | 1600 L |
| Temperature range | Ambient to +60°C |
| Humidity range | 95% to 98% RH |
| Temperature Fluctuation | ± 0.5 ℃ |
In order to increase the durability of product, we need to test its performance under various conditions. Keeping this in mind, Labtron presents sand test chambers which simulate dust and sand conditions in a controlled atmosphere.
| Temperature range | Ambient to + 50 ℃ |
| Relative Humidity | < 30 % RH |
| Normal wire diameter | 50 um |
| Normal width of a gap between wire | 75 um |
| Temperature range | Ambient to + 50 ℃ |
| Relative Humidity | < 30 % RH |
| Normal wire diameter | 50 um |
| Normal width of a gap between wire | 75 um |
| Temperature range | Ambient to + 50 ℃ |
| Relative Humidity | < 30 % RH |
| Normal wire diameter | 50 um |
| Normal width of a gap between wire | 75 um |
| Temperature range | Ambient to + 50 ℃ |
| Relative Humidity | < 30 % RH |
| Normal wire diameter | 50 um |
| Normal width of a gap between wire | 75 um |
Labtron offers temperature and humidity test chambers which are used in various industries to test large equipments such as automotive parts by controlling the temperature and humidity. It is highly stable and provides enough space to work.
| Capacity | 50 L |
| Temperature range | (- 20 °C) to 150 °C |
| Low type | I – 40 °C, II – 70 °C |
| Environmental condition | 5 ℃ ~ + 40 ℃ ≤ 85 % RH |
| Capacity | 80 L |
| Temperature range | (- 20 °C) to 150 °C |
| Low type | I – 40 °C, II – 70 °C |
| Environmental condition | 5 ℃ ~ + 40 ℃ ≤ 85 % RH |
| Capacity | 100 L |
| Temperature range | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 1 ℃ / min |
| Overall dimension (D x W x H) | 860 x 1050 x 1620 mm |
| Capacity | 225 L |
| Temperature range | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 1 ℃ / min |
| Overall dimension (D x W x H) | 960 x 1150 x 1860 mm |
| Capacity | 500 L |
| Temperature range | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 1 ℃ / min |
| Overall dimension (D x W x H) | 1180 x 1350 x 2010 mm |
| Capacity | 800 L |
| Temperature range | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 1 ℃ / min |
| Overall dimension (D x W x H) | 1280 x 1550 x 2110 mm |
| Capacity | 1000 L |
| Temperature range | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 1 ℃ / min |
| Overall dimension (D x W x H) | 1500 x 1550 x 2110 mm |
| Capacity | 100 L |
| Temperature range | (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 5 ℃ / min |
| Overall dimension (D x W x H) | 860 x 1050 x 1620 mm |
| Capacity | 225 L |
| Temperature range | (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 5 ℃ / min |
| Overall dimension (D x W x H) | 960 x 1150 x 1860 mm |
| Capacity | 500 L |
| Temperature range | (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 5 ℃ / min |
| Overall dimension (D x W x H) | 1180 x 1350 x 2010 mm |
| Capacity | 800 L |
| Temperature range | (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 5 ℃ / min |
| Overall dimension (D x W x H) | 1280 x 1550 x 2110 mm |
| Capacity | 1000 L |
| Temperature range | (-70 )℃ to 150 ℃ |
| Temperature cooling rate | 5 ℃ / min |
| Overall dimension (D x W x H) | 1500 x 1550 x 2110 mm |
| Capacity | 3150 L |
| Temperature range | -40℃ to 150℃ |
| Temperature cooling rate | 1℃ / min |
| Temperature heating rate | 1℃ / min |
| Interior Volume | 700 L |
| Heat load | 1000 W |
| Temperature Range | 10℃ to +50 ℃ |
| Temperature Deviation in time | ± 0.1 to 0.3 ℃ |
| Capacity | 150 L |
| Temperature range | 10 to 70°C |
| Temperature stability | High: ±0.5℃; Low: ±1℃ |
| Temperature uniformity | ±2°C |
We manufacture Xenon test chambers which consist of xenon lamp to simulate environmental factors to test its effect on products. It is widely used in research, product development and quality control.
| Temperature Range | RT+50℃ to 70℃ |
| Temperature Fluctuation | ±3℃ |
| Cooling Way | Air-cooled |
| Raining Time | 0-99min adjustable |
| Bandwidth Measurement (nm) | 280 ~ 800 |
| Specimen Capacity (pcs) | 28 |
| Specimen holder size (mm) | 80 × 15 |
| Chamber Temperature Range | Ambient ~ 100 ℃ ± 2 °C |
| Bandwidth Measurement (nm) | 300 - 420 |
| Specimen Capacity (pcs) | 34 |
| Specimen holder size (mm) | 80 × 15 |
| Chamber Temperature Range | Ambient ~ 100 ℃ ± 2 °C |
| Bandwidth Measurement (nm) | 280 ~ 800 |
| Specimen Capacity (pcs) | 28 |
| Specimen holder size (mm) | 80 × 15 |
| Chamber Temperature Range | Ambient ~ 100 ℃ ± 2 °C |
| Bandwidth Measurement (nm) | 300 - 420 |
| Specimen Capacity (pcs) | 34 |
| Specimen holder size (mm) | 80 × 15 |
| Chamber Temperature Range | Ambient ~ 100 ℃ ± 2 °C |