Ask An Expert

Whiteness and chromaticity tester TP-A10
Accuracy: Chromaticity co-ordinate 0.0001
Dimension (L*W*H): 360 × 264 × 400 mm
Light measurement: CIE whiteness (Ganz whiteness W10, Color cast value TW10), WH hunter whiteness, YI Yellowness, ISO brightness R457
Measurement mode: Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Whiteness meter TP-A11
Dimension (L*W*H): 360 × 264 × 400 mm
Indication drift: ≤ 0.1 %
Indication error: ≤ 0.5 %
Light source: D65 as illuminating source
Tensile Stiffness Tester TP-B10
Dimension (L*W*H): 220 × 230 × 350 mm
Indication error: 0.02
Measuring range: (1-500) mN.m (divided into 7 small ranges)
Net weight: 15 kg
Automatic horizontal tensile tester TP-B11
Accuracy: ± 1 %
Clamp air pressure: 0.4 to 0.6 MPa
Dimension (L*W*H): 920 × 420 × 300 mm
Measuring range: 0 to 30, 0 to 100 N,0 to 300 N
Automatic horizontal tensile tester TP-B12
Accuracy: ± 1 %
Dimension (L*W*H): 800 × 270 × 200 mm
Measuring range: 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Net weight: 40 kg
Vertical tensile tester TP-B20
Accuracy: ± 1 %
Dimension (L*W*H): 450 × 550 × 120 mm
Measuring range: 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Net weight: 55 kg
Pulp beating (refining) freeness tester TP-C10
Dimension: 450×250×1100 mm
Draining time: 149 ± 1 s
Hydraulic pressure: >0.3 MPa
Measurement range: 0 to 100° SR
Water absorption tester TP-C20
Dimension: 420×250×380 mm
Division value: 1 mm
Measurement range: 0 to 200 mm
Net Weight: 15 kg
Water absorption tester- Cobb Tester TP-C21
Absorbency paper: 200 to 250 g/m2
Absorbency speed: 75 mm/10 min
Dimension: 270×400×300 mm
Metal Cylinder height: 50 mm
COBB sample cutter TP-C30
Dimension: 240×288×435 mm
Net Weight: 25 kg
Sample diameter: 125 mm
Sample error: ± 0.2 mm
Coefficient of friction tester TP-D10
Dimension of working plate: 170×225 mm
Measurement range: 0.01 to 10 N
Slider size: 63×63 mm
Slider stroke: Max 100 mm (adjustable)
Electronic bending stiffness tester TP-E10
Bend angle: 1 to 90°
Dimension: 200×230×350 mm
Indicating Error: ± 1 %
Power supply: AC220 V ± 10 % , 50 Hz
Paper and cardboard thickness meter TP-E20
Accuracy: 0.01 or 0.001 mm
Contact diameter: 16.0 ± 0.5 mm
Contact pressure (to create false weight): 100 ± 10 kPa
Dimension: 233×160×120 mm
Paper and cardboard thickness meter TP-E21
Accuracy: 0.01 mm
Contact diameter: 35.7 ± 0.5 mm
Contact pressure (to create false weight): 20 ± 0.5 kPa
Dimension: 233×160×120 mm
Ink rubber tester TP-F10
Dimension: 275×302×297 mm
Friction area (L*B): 155×50 mm
Friction speed: 43 times / min
No. of friction: 0 to 999, auto shutdown
Standard strip cutter TP-G10
Dimension: 240×520×70 mm
Parallelism: ≤ 0.1 mm
Sample maximum length: 300 mm
Sample width: 15 mm
Softness tester TP-H10
Accuracy: ± 1%
Dimension: 570×410×200 mm
Division value: 1 mN
Indicating Error: ≤ 0.5
Carton compression tester TP-I10
Compression speed: 10 mm/ min
Indication error: < ± 1%
Measuring range: 0.1 to 10 kN
Operating stroke: 500 mm (customized)
Carton compression tester TP-I11
Compression speed: 10 mm/ min
Indication error: < ± 1%
Measuring range: 1 to 50 kN
Operating stroke: 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Paper air permeability tester TP-J10
Area differential pressure: 1 ± 0.01 kPa
Dimension: 410×300×1160 mm
Inner diameter of grip ring: 35.68 ± 0.05 mm
Measuring range: 0 to 1000 ml/min
Internal Ply bond Tester TP-J11
Capacity: A: 20 to 500 J/m2 B: 500 to 1000 J/m2
Dimension: 700×340×600 mm
Error: A: ± 1 J/m2 B: ± 2 J/m2
Impact angle: 90°
Puncture strength tester TP-J12
Dimension: 800×470×840 mm
Frictional resistance: <0.25 J
Measuring range: A (1 to 6) J indicating error ± 0.05 J
B (1 to 12) J indicating error ± 0.05 J
C (1 to 24) J indicating error ± 0.05 J
D (1 to 48) J indicating error ± 0.05 J
The indicating errors w.r.t measurement range of 20 to 80 %
Power supply: AC220 V ± 10 % , 50 Hz
Paper tearing tester TP-J20
Indication error: ± 1 %
Measuring range: 0 to 1000 mN
Resolution: 0.1 mN
Tearing angle: 27.5° ± 0.5°
Electronic Tearing tester TP-J21
Capacity: 10 -16000 mN
Chips distance: 180 mm
Clamp- paper: 2.8 ± 0.3 mm
Resection length: 20 ± 0.5 mm
Mullen burst tester TP-K10
Accuracy: ± 0.5 % F.S.
Clamp pressure: ≥ 690 kPa
Compression speed: 170 ± 15 ml/min
Diameter of lower clamp: 31.5 ± 0.05 mm
Mullen burst tester TP-K11
Accuracy: ± 0.5 % F.S.
Clamp pressure: ≥ 430 kPa
Compression speed: 95 ± 5 ml/min
Diameter of lower clamp: 33.1 ± 0.05 mm
Crush tester TP-L10
Accuracy: ± 1 %
Dimension: 450×400×500 mm
Maximum distance: 78 mm
Measurement range: 5 to 500 N, 50 to 3000 N
Bekk Smoothness tester TP-L20
Accuracy: ±0.1 s within 300 s
Air volume (50.66 kPa down to 48.00 kPa): Big vacuum volume: 10.00 ± 0.20 ml
Small vacuum volume: 1.00 ± 0.05 ml
Contact pressure: 100 ± 2 kPa
Dimension: 325×390×430 mm
Folding endurance tester TP-M10
Dimension: 320×320×450 mm
Folding head suture size: 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Folding angle: 135° ± 2°
Folding radius: 0.38 ± 0.02 mm

Enquiry Now