Angular Spectrometer LASM-A10
Angle Measurement Accuracy: 1inch
Optical Parameter: {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"}
Divided Circle: {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"}
Stage: {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"}
Atomic Fluorescence Spectrometer LAFS-A10
Beam Configuration: Dual Channel
Elements ( Measuring Range ): {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"}
Precision ( RSD ): < 1.0
Linear range: More than 3 orders of magnitude
FTIR Spectrometer LIR-B10
Spectral Range: 7800 cm-1 to 350 cm-1
Resolution: 0.85 cm-1
Wave number precision: ± 0.01 cm-1
Scanning speed: Microprocessor control, different scanning speed selectable
ICP spectrometer LICP-A10
Wavelength range ( 3600 lines / mm ): 180 to 500 nm
Wavelength range ( 2400 lines / mm ): 180 to 800 nm
Temperature: 20 ~ 28 °C
Elements per minute: 26 elements
ICP Spectrometer LICP-B10
Monochromator Specifications: {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"}
Solid State Power Specifications: {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"}
Technical Specifications: {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"}
Control Circuit: {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"}
ICP Spectrometer LICP-A11
Wavelength range: 180 to 900 nm
Elements per minute: 15 elements
Temperature: 29 °C
Incident slit: 25 µm
ICP Spectrometer LICP-A12
Wavelength range: 195 to 800 mm
Elements per minute: 10 elements
Temperature range: 32 °C
Incident slit: 20 µm
XRD Diffractometer LXRD-A10
X-ray Tuble: Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW
Focus Size: 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm
Stability: ≤ 0.01 %
Tube Current: 5 to 80 mA
XRF-Spectrometer LXRF-A10
Measureable elements: S to U
Detection limit: 1 ppm
Temperature: 15 ~ 30 °C
Elemental content: 1 ppm to 99 %
Handheld XRF Spectrometer LXRF-B10
Analytical Method: Energy dispersive X-ray fluorescence analytical Method
Elements Measuring: Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
Range: Simultaneous detector
Content measurement range: ppm to 100%
Handheld XRF Spectrometer LXRF-B11
Analytical Method: Energy dispersive X-ray fluorescence analytical Method
Elements Measuring: Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
Range: Simultaneous detector
Content measurement range: ppm to 99.99%