Ask An Expert
ICP Spectrometer LICP-B10 is an instrument which measures elements in ppb levels with least interference and reduces the time taken for analysis by detecting 5 to 6 elements in 1 min. Excellent analytical precision, high optical resolution, fully automated, wide wavelength range with 2400 line grating, powerful analysis software, high performance solid-state RF system, high accuracy etc. are some of the characteristic features. The equipment consist of a Scott-type spray chamber, quartz torch, spectrophotometer with Czerny-Turner monochromator, detector with photomultiplier tube and data processing system which allows multi-element measurement along with high resolution. It finds applications in environmental, food safety, metallurgy, pharmaceutical etc. fields.
It used for quantitative and qualitative analysis of elements in the given sample. Various fields like petrochemicals, pharmaceuticals, agriculture, environmental, food industry, metallurgy, processing industry etc. require it for several operations.
| Wavelength range ( 3600 lines / mm ) | 180 to 500 nm |
| Wavelength range ( 2400 lines / mm ) | 180 to 800 nm |
| Temperature | 20 ~ 28 °C |
| Elements per minute | 26 elements |
| Wavelength range | 180 to 900 nm |
| Elements per minute | 15 elements |
| Temperature | 29 °C |
| Incident slit | 25 µm |
| Wavelength range | 195 to 800 mm |
| Elements per minute | 10 elements |
| Temperature range | 32 °C |
| Incident slit | 20 µm |
| Spectral Range | 7800 cm-1 to 350 cm-1 |
| Resolution | 0.85 cm-1 |
| Wave number precision | ± 0.01 cm-1 |
| Scanning speed | Microprocessor control, different scanning speed selectable |
| Beam Configuration | Dual Channel |
| Elements ( Measuring Range ) | {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"} |
| Precision ( RSD ) | < 1.0 |
| Linear range | More than 3 orders of magnitude |
| Measureable elements | S to U |
| Detection limit | 1 ppm |
| Temperature | 15 ~ 30 °C |
| Elemental content | 1 ppm to 99 % |
| Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
| Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
| Range | Simultaneous detector |
| Content measurement range | ppm to 100% |
| Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
| Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
| Range | Simultaneous detector |
| Content measurement range | ppm to 99.99% |
| X-ray Tuble | Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW |
| Focus Size | 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm |
| Stability | ≤ 0.01 % |
| Tube Current | 5 to 80 mA |
| Angle Measurement Accuracy | 1inch |
| Optical Parameter | {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"} |
| Divided Circle | {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"} |
| Stage | {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"} |