XRF-Spectrometer LXRF-A10 is a microprocessor controlled high-count throughput unit with low detection limits for wide range of elements. Provision of multi-elemental analysis with detection limits upto 1 ppm. Built-in movable platform for easy location of testing point.High resolution detector improves analysis accuracy. Equipped with safety features of optical tube shielding with no X-ray radiation and high voltage emergency locking.
Used in detection of plating thickness of metals, concentration of plating solution , RoHS detection and analysis, full-element analysis and electro plating industries
| Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
| Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
| Range | Simultaneous detector |
| Content measurement range | ppm to 100% |
| Analytical Method | Energy dispersive X-ray fluorescence analytical Method |
| Elements Measuring | Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured |
| Range | Simultaneous detector |
| Content measurement range | ppm to 99.99% |
| Spectral Range | 7800 cm-1 to 350 cm-1 |
| Resolution | 0.85 cm-1 |
| Wave number precision | ± 0.01 cm-1 |
| Scanning speed | Microprocessor control, different scanning speed selectable |
| Beam Configuration | Dual Channel |
| Elements ( Measuring Range ) | {"As, Se, Pb, Bi, Sb, Te, Sn":"< 0.01 \u00b5g\/L","Hg, Cd":"< 0.001 \u00b5g\/L","Zn":"< 1.0 \u00b5g\/L","Ge":"< 0.1 \u00b5g\/L"} |
| Precision ( RSD ) | < 1.0 |
| Linear range | More than 3 orders of magnitude |
| Wavelength range ( 3600 lines / mm ) | 180 to 500 nm |
| Wavelength range ( 2400 lines / mm ) | 180 to 800 nm |
| Temperature | 20 ~ 28 °C |
| Elements per minute | 26 elements |
| Monochromator Specifications | {"Optical type":"Czerny turner","Resolution":"\u2264 0.015nm (3600 line grating) \u2264 0.030nm (2400 line grating)","Focal length":"1000 mm","Grating specifications":"huge holographic grating with 3600 L\/mil or 2400 L\/mil and 80 mm \u00d7 100 mm of ruling area","Wavelength range":"195 to 500 nm for 3600 line grating 195 to 800 nm for 2400 line grating"} |
| Solid State Power Specifications | {"Frequency":"27.12 MHz Frequency stability: < 0.05%","Spray chamber":"Scott double pass spray chamber","Output power":"800 W to 1600 W, adjustable with power efficiency more than 65%","Output power stability":"\u2264 0.05%","Induction coil":"25 mm \u00d7 3 ID (ID-internal diameter), equipped with three concentric quartz torch tubes 35 mm ED (ED-external diameter)"} |
| Technical Specifications | {"Suitable sample content range":"Liquid sample: 0.01 ppm to several thousand ppm Solid or power sample: 0.001% to 70%","Repeatability":"short-term stability- RSD \u2264 1.5% Long-term stability: RSD \u2264 2%","Test speed":"5 to 8 elements \/ min","Limits of detection (LOD, \u00b5g\/L) for most elements":"1ppb to 10ppb"} |
| Control Circuit | {"Photomultiplier tube specification":"R212 \/ R928","Negative high voltage":"-50 to -1000 V","Circuit measuring range":"(10-12<\/sup> to 10 -4<\/sup>) A","Signal acquisition":"VF conversion"} |
| Wavelength range | 180 to 900 nm |
| Elements per minute | 15 elements |
| Temperature | 29 °C |
| Incident slit | 25 µm |
| Wavelength range | 195 to 800 mm |
| Elements per minute | 10 elements |
| Temperature range | 32 °C |
| Incident slit | 20 µm |
| X-ray Tuble | Glass tube, Ceramic tube, Ripple Ceramic tube: Cu, Fe, Co, Cr, Mo etc., Power 2 kW |
| Focus Size | 1 × 10 mm/ 0.4 × 14 mm/ 2 × 12 mm |
| Stability | ≤ 0.01 % |
| Tube Current | 5 to 80 mA |
| Angle Measurement Accuracy | 1inch |
| Optical Parameter | {"Focal Length":"170 mm","Effective Aperture":"\u03a6 22 mm","Field of View":"3\u00b0 22inch","Focal Length of Telescope\u2019s Eyepiece":"24.3 mm","Maximum Length Between Collimator and Telescope":"120 mm","Slit Width":"0.02 to 2 mm","Diopter Compensation Range":"\u2265 \u00b1 5 diopters"} |
| Divided Circle | {"Diameter":"\u03a6178 mm","Circle Graduation":"0\u00b0 to 360\u00b0","Division":"0.5\u00b0","Vernier Reading Value":"1inch"} |
| Stage | {"Diameter":"\u03a670 mm","Rotating Range":"360\u00b0","Range of Vertical Adjustment":"20 mm"} |